High-temperature thermal paper

High-temperature thermochromic paper contains a thermosensitive coating that undergoes reversible or irreversible color changes when heated. It is used to mark the surface temperature of objects and indicate temperature status in applications such as industrial heat treatment and equipment temperature measurement.
Selection
Select the product with the corresponding color-changing temperature based on the actual temperature measurement range. Consider factors such as the clarity of the color change, response time, and the temperature resistance of the substrate. Choose between disposable or reversible types based on the usage environment, and pay attention to storage conditions to avoid premature failure.

Terms

Instruments

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Using irreversible discoloration technology to accurately record the highest temperature experienced, 8-grid rectangular temperature points cover the range of 160 ° C to 199 ° C, with oil and water resistance and ISO 9001 standard, accuracy of +/- 1% range.

$ 92.00

Using irreversible discoloration technology, 8 temperature points accurate monitoring, Precision up to +/- 1 ℃, with oil and water resistance, in line with ISO 9001 standard, size 51 * 18mm easy to paste use.

$ 89.00

Using triple-channel thermal insulation structure, the damper switching time is completed within 10 seconds, and the temperature recovery time is within 5 minutes. With 96 test specification settings, the maximum Impact time is 9999 minutes, meeting the needs of high and low temperature rapid change testing.

$ 27829.00

Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.

$ 16372.00

Adopt variable frequency motor control to achieve 50 +/- 5mm/min compression speed, equipped with thermal printer to achieve high-speed silent printing, effective Travel up to 400mm and platen spacing can be arbitrarily set 0-500mm.

$ 1747.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Measurement range 10~ 16000mN, resolution 0.1mN, pneumatic fixture to ensure stable clamping, thermal printer real-time output test data, suitable for a variety of sheet material Tear strength detection.

$ 2066.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time up to 9999 minutes, with 96 test specifications independently set and automatic defrosting function.

$ 22019.00

Adopt triple-channel thermal insulation structure to realize cold and hot air circuit switching, temperature recovery time within 5 minutes, Impact time can reach 9999 minutes. With 96 test specification settings and P.I.D automatic calculation control to ensure Test accuracy.

$ 20228.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

Articles