Large Climate Test Chamber

The large climate test chamber simulates changes in the natural environment through its temperature and humidity control system, and is used to test the tolerance of materials under conditions such as damp heat and dry cold. It is widely applied in the aging testing and quality verification of products such as electronic components, automotive parts, and coatings.
Selection
When selecting, consider the temperature and humidity range and control accuracy required by the testing standards. The chamber volume should match the sample size. Pay attention to the cooling method, sensor type, and energy consumption indicators. Ensure the equipment material is corrosion-resistant and equipped with data recording functionality.
light intensity
volume
constant temperature fluctuation

Terms

Standards

Instruments

Using stainless steel liner and ultra-fine fiberglass insulation cotton, Temperature range -60~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, equipped with large screen Touchscreen and 100 sets of program storage, support RS-232/485 communication.

$ 5754.00

Using stainless steel liner and ultra-fine fiberglass insulation cotton, Temperature Uniformity ≤ +/- 2 ℃, Fluctuation ≤ +/- 0.5 ℃, equipped with large screen Touchscreen and 100 sets of program capacity, support RS-232/485 communication, improve test accuracy and convenience.

$ 10143.00

The 7.0-inch large screen is easy to operate, equipped with a French Taikang Compressor unit, Temperature Fluctuation ≤ +/- 0.5 ° C, humidity deviation + 2, -3% R.H, independent temperature and humidity system to improve efficiency.

$ 4027.00

800L large volume design, temperature control accuracy of +/- 1 ℃, with six adjustable lighting system, support 30 sets of program settings, mirror stainless steel liner for easy cleaning, independent temperature limit alarm to ensure safe operation.

$ 7871.00

The 7.0-inch large screen is easy to operate, equipped with French Taikang fully enclosed Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2, -3% RH, support 0~ 9999 minutes timing and independent temperature limit alarm.

$ 7980.00

With -60~ 150 ℃ wide temperature range and 30~ 98% RH humidity control, multi-wing air supply cycle to ensure uniform temperature and humidity, 7.0 inch large screen programmable controller supports 100 sets of programs to improve test efficiency and accuracy.

$ 8142.00

250L large capacity design, support 0-12000LX six-level adjustable light, mirror stainless steel liner is easy to clean, 30 sets of programs can be set to meet long-term experimental needs, independent temperature limit alarm system to ensure safe operation.

$ 2249.00

The 7.0-inch large screen is easy to operate, equipped with a French Taikang fully enclosed Compressor unit, Temperature Uniformity ≤ +/- 2 ° C, humidity deviation + 2, -3% R.H, independent temperature limit alarm system to ensure experimental safety.

$ 3494.00

Adopt stainless steel air duct and centrifugal fan, the wind speed is adjustable, the dust concentration is 2.0~ 4.0kg/m ³, support vertical circulation and dust drying, ensure test uniformity and data accuracy.

$ 8093.00

Adopting stainless steel air duct and centrifugal fan, the wind speed can be adjusted, the dust concentration is 2.0~ 4.0kg/m ³, and it has the function of vertical circulation air flow and dust drying to ensure the accuracy and uniform dispersion of test data.

$ 10353.00

Adopt stainless steel air duct and centrifugal fan, dust concentration 2.0~ 4.0kg/m ³, liner size 1000 * 1500 * 1000mm, support vertical circulation air flow and dust drying function, ensure accurate and reliable test data.

$ 9465.00

Volume 800L, Temperature range 4-50 ℃, light intensity 0-30000LX, support 30 sets of program settings, with independent temperature limit alarm system and mirror stainless steel liner design.

$ 7180.00

Adopt stainless steel air duct and vertical circulation air flow system, equipped with frequency converter to adjust the wind speed, dust concentration 2.0~ 4.0kg/m ³, built-in vibration and drying device to ensure the accuracy of test data.

$ 6334.00

With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.

$ 1845.00

Using stainless steel liner and ultra-fine fiberglass insulation cotton, Temperature Uniformity ≤ +/- 2 ° C, Fluctuation ≤ +/- 0.5 ° C, support 100 program editing and RS-232 communication to ensure accurate and efficient testing.

$ 9223.00

Articles

The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
Contact Angle Meter Evaluates Wettability of Hydrophobic Coatings
A contact angle measuring instrument evaluates the wettability of hydrophobic coatings by analyzing the angle formed by a liquid droplet on a solid surface. Its principle is based on Young's equation, where a contact angle greater than 90° indicates hydrophobicity.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
IGT Printability Tester Evaluates Paper Surface Pick Resistance
This article introduces how to use the IGT printability tester to evaluate the surface pick resistance of paper. Picking refers to the phenomenon where the tack force of the ink is too high during printing, causing the surface fibers of the paper to be lifted, which affects print quality.
Application of Paperboard Burst Strength Tester in Packaging Materials
The paperboard bursting strength tester is a detection device used to measure the ability of packaging materials such as paperboard to resist rupture under vertical pressure. During the test, the sample is clamped between annular clamps, and increasing pressure is applied via hydraulic or pneumatic means until rupture occurs. The maximum pressure value is recorded as the bursting strength.