$ 9223.00Ex works
Using stainless steel liner and ultra-fine fiberglass insulation cotton, Temperature Uniformity ≤ +/- 2 ° C, Fluctuation ≤ +/- 0.5 ° C, support 100 program editing and RS-232 communication to ensure accurate and efficient testing.
Category : High Low Temperature Test Chamber
Brand : ZKHS
SKU : NB026937
Service :The delivery and service By NBCLab.Com
GDW-800C low/high temperature test chamber is produced by ZKHS, suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products and various electronic components in high and low temperature or heat and humidity environment inspection of its performance indicators. Inner chamber dimensions of the equipment are 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, using advanced temperature and humidity control system and refrigeration technology to ensure accurate and stable testing.
1. The box body is processed and formed by numerical control machine tool, which is beautiful and easy to operate. 2. The liner is imported stainless steel (SUS304) mirror plate, and the shell is sprayed with A3 steel plate to improve the appearance texture and cleanliness. 3. The replenishment tank is equipped with automatic water shortage protection, which is convenient for water replenishment. 4. Large observation window with lighting, embedded tempered Glass, clear observation of the situation inside the box. 5. The humidification system piping is separated from the control circuit board to improve safety. 6. Waterways and circuit systems are door-opened for easy maintenance and repair. 7. Insulation adopts ultra-fine fiberglass insulation cotton to reduce energy loss. 8. The left side of the box is equipped with a 50mm diameter test hole for external test lines. 9. Temperature and humidity control instrument for 7.0 inch large screen, support Chinese and English interface, real-time display operation Linear dispersion. The controller has a capacity of 100 programs and 1000 cycles of 999 steps, with a maximum setting of 99 hours and 59 minutes per cycle. 11. With screen lock function to prevent accidental touch shutdown. 12. Supports RS-232 or RS-485 communication interface, allowing for computer programming and monitoring. 13. Automatic calculation function, real-time correction of temperature and humidity changes, more accurate control. 14. The refrigerator adopts the original French "Taikang" fully enclosed Compressor. 15. The refrigeration system adopts a unit or binary cryogenic circuit design. 16. The multi-wing blower has a strong circulation, uniform temperature and humidity distribution, and fast recovery time. 17. The heating system is fully independent nickel-chromium alloy electric heating type. 18. Safety protection includes leakage, short circuit, overheating, motor overheating, Compressor overvoltage, overload, overcurrent protection.
The low/high temperature test chamber adopts the original French "Taikang" fully enclosed Compressor and unit or binary low temperature circuit design through the refrigeration system to achieve rapid cooling and temperature control. The heating system uses a fully independent nickel-chromium alloy electric heater to heat up, combined with a multi-wing blower strong circulation air path to ensure uniform distribution of temperature and humidity in the test area. The temperature and humidity control instrument corrects the environment changes in real time through the automatic calculation function to maintain accurate and stable, and supports program editing and remote monitoring.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Connect the power supply to ensure that the voltage is AC280V +/- 10% or AC380V +/- 10%, 50Hz three-phase five-wire system. 2. Open the control instrument, select the Chinese and English interface, and edit or select the test program. 3. Set the temperature range, time and other parameters, each time can be set up to 99 hours and 59 minutes. 4. Start the device, observe the screen real-time Linear dispersion, and monitor the test process. 5. After the test is completed, turn off the device and disconnect the power.
• Operating Environment Temperature should be 5 ℃~ 30 ℃, humidity ≤ 85% R.H. • Regularly check the replenishment tank to avoid protection triggers caused by water shortage. • During maintenance, use the door opening design for waterway and circuit system maintenance. • Avoid artificially touching the controller screen to prevent misoperation and shutdown. • The test hole is closed in time after use to prevent energy loss. • Pay attention to the status of the safety protection device when the equipment is running, and immediately stop for inspection in case of abnormality.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.