Split-type Light Meter

The split-type light meter consists of a probe and a main unit. The probe detects light intensity and converts it into an electrical signal, while the main unit displays the numerical values. It is used to measure lighting conditions in scenarios such as paint curing and printing exposure.
Selection
When selecting, consider matching the measurement range with application requirements, ensuring the probe size fits the detection location, verifying that the main unit functions meet reading and recording needs, and paying attention to the impact of environmental temperature on accuracy.

Terms

Instruments

Split design with super magnetic automatic suction, can be directly tested on the installed film Glass, using 1400nm Infrared source and 365nm UV light source, measurement accuracy of +/- 2%, with laser alignment function to ensure measurement accuracy.

$ 390.00

With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.

$ 107.00

The main and auxiliary machine split design is convenient for on-site measurement, three independent test units are averaged to improve accuracy, built-in lithium battery power supply is convenient to carry, laser alignment ensures accurate measurement, Measurement accuracy +/- 2%.

$ 357.00

Glass transmittance measurement is facilitated by split dual-machine design, integrated UV-IR-VIS 3-in-1 test function, equipped with laser alignment to ensure measurement accuracy +/- 2%, and supports built-in lithium battery power supply.

$ 357.00

Ultra-small portable design, can be carried in the pocket; use a AA battery, continuous operation of tens of thousands of sets of data; that is, open and test, no need to wait; D65 Illuminant, 0.2% Repeatability, eliminate external rays of light interference, accurate data.

$ 444.00

Split design supports two test modes, Measurement accuracy +/- 2%, resolution 0.10%, equipped with 2.3 inch color screen and 2000 sets of Data storage functions, to adapt to the field rapid measurement needs.

$ 590.00

Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.

$ 444.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support split probe flexible replacement, with automatic identification of matrix material function, minimum measurable surface radius 1.5mm.

$ 419.00

With split Probe design, equipped with F and N Probe, Measurement range 0~ 1500 microns, resolution 0.1 microns, automatic identification of substrate type, support for more than 60 readings per minute, Protection Rating IP65.

$ 1476.00

Sensor and host split design, measurement range 3-80%, accuracy +/- 0.5%, support 37 kinds of grain type measurement, with temperature and humidity compensation function, Response Time is only 1 second, Portable structure is convenient for on-site rapid detection.

$ 186.00

With 1-200000Lux wide range automatic switching function, Sampling rate 2 times/second, Response Time 1 second, support Lux/Fc unit display, portable split design for on-site detection.

$ 104.00

The instrument adopts ultra-small portable design, equipped with protective rubber sleeve to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data; with D65 visible light, 940NM infrared and 350NM ultraviolet three Illuminants, Repeatability of 0.2%.

$ 751.00

Split structure design, Measurement accuracy +/- 2%, resolution up to 0.1%, support single and continuous Measurement mode, data transmission via USB and Bluetooth connection, suitable for a variety of transparent material inspection.

$ 299.00

Split structure is easy to carry, supports free conversion of six Hardness units, can store 50 sets of test data, Measurement range 200~ 900HLD, with RS232 interface and backlight display function.

$ 377.00

Using split Sensor design, temperature range -20~ 60 ℃, humidity range 10~ 95% RH, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, compact and easy to carry.

$ 211.00