Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.
Supports more than 30 chroma indicators, Measurement accuracy ≤ E * ab ≤ 0.01, single measurement only takes 1.5 seconds, minimum liquid addition is as low as 1ml, equipped with thermostatic sample tank and 7 inch Touchscreen.
Suitable for reflection color measurement of high concentration liquids, sauces and powder samples, the Cuvette bracket design ensures that the measurement environment is completely black to ensure the accuracy and Stability of measurement results.
Using D/0 geometrical optics structure and full light spectrum LED Illuminant, covering 360-780nm wavelength, Repeatability chromatic value within 0.015, support multi-element Illuminant simulation and rich chroma indicators to ensure measurement Stability and accuracy.
Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.
Adopt D/8 ° illumination and Φ 58mm integrating ball, repeability accuracy Delta E * ab within 0.04, support liquid, powder and other sample testing, equipped with 3.5 inch capacitive Touchscreen and large capacity storage.
Using D/8 lighting system, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration technology to ensure measurement accuracy, lithium battery supports 12,000 consecutive tests.
The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.
It has a multi-function smart button design, supports more than 30 Color indicators and 28 kinds of observation Illuminants, adopts non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 is less than 0.2, high measurement Stability, portable and lightweight only 88 grams.
Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.
Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.
Adopt internationally recognized LOVIBOND color scale, measurement range red 0.1-79, yellow 0.1-79, blue 0.1-49 LOVIBOND units, minimum indication 0.1, equipped with three specifications Cuvette to meet multi-sample testing needs.
Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.
Pellon liquid junction is used to ensure uniform Flow velocity, circular Glass sensitive film fully senses pH value, Measurement range 0~ 14pH, Operating temperature 0~ 60 ℃, the structure is not easy to damage.
Suitable for laboratory sampling test, high corrosion resistance, can measure a variety of material density, with sampling test type for liquid special anti-corrosion accessories.