Single-Blade Adhesion Cutter

The single-blade cross-cut tester evaluates adhesion by cutting a grid pattern on the coating surface with a blade and observing the degree of coating peeling. It is used to test the bonding strength between coatings (such as paints and inks) and substrates, aiding in the assessment of coating durability.
Selection
When selecting, consider the coating thickness matching the blade specifications, the handle design affecting operational stability, the mesh size needing to comply with testing standards, the blade material determining durability, and the overall structure facilitating easy maintenance and cleaning.
Tooth spacing
Number of teeth
Test substrate
Measured film thickness
Number of blades
Applicable standard
Miscellaneous

Terms

Standards

Instruments

11 tooth cutter design, 2mm pitch, single-sided simple cutter head, can carry out cross-cut experiment, test coating adhesion, in line with a number of international standards.

$ 186.00

The number of teeth is 11, the spacing is 1mm, and the single-sided simple cutter head design can be used for cross-cutting experiments. Standard two cutter heads are provided for easy operation.

$ 186.00

Equipped with 1mm and 2mm cutter head spacing, the number of cutter teeth is 11, which can meet the needs of different paint film thickness testing, easy to operate and in line with international standards.

$ 186.00

Made of stainless steel, with 6 cutter teeth, the cutter tooth spacing is 2mm, which can provide a uniform cutting effect and is suitable for paint film adhesion testing.

$ 154.00

The circular cutter is designed with eight incisions and 1mm spacing between the teeth. It is suitable for strong substrate adhesion testing with a Coating thickness of less than 60 microns and meets the requirements of ISO 2409.

$ 860.00

Equipped with three swirl/spin cutter heads, the tooth spacing is 1mm, 2mm and 3mm respectively, and it is designed according to ISO2409 standard for accurate evaluation of coating adhesion performance.

$ 183.00

Adopting 6 cutter face circumference multi-face cutter tooth structure, the service life is significantly improved. The cutter tooth spacing is 1mm, which is suitable for the testing requirements of solid substrates with film thickness below 60μm.

$ 186.00

Adopting 6 cutter face circumference multi-face cutter tooth design, the service life is significantly extended; the number of cutter teeth is 11, and the spacing is 2mm, which is suitable for hard substrate testing in the range of 60-120μm film thickness.

$ 186.00

The ergonomic handshake design is labor-saving, and the blade can be easily replaced; the top width of the blade is less than 0.05mm, and the included angle is 30 ° +/- 1 ° to ensure accurate and clear scratches and improve test accuracy.

$ 151.00

Using high-quality alloy steel blades, the top width of the blade is less than 0.05mm, the angle of the blade is 30 ° +/- 1 °, the ergonomic handshake design is lightweight, and the blade can be quickly replaced to meet a variety of standard testing requirements.

$ 151.00

11 teeth blade design, 1.5mm isometric cutting, equipped with automatic adjustment of the blade holder to ensure pressure Balance, circular cutter with eight incisions, suitable for 50-125μm film thickness environment test.

$ 947.00

Made of stainless steel, with 6 cutter tooth designs, with a cutter tooth spacing of 3mm, strong durability and stable cutting effect, suitable for accurate paint film testing requirements.

$ 154.00

The number of teeth 6, spacing 3mm, using circumferential multi-faceted cutter surface design, long service life, suitable for film thickness greater than 120 μ m hard substrate test cross-cut.

$ 186.00

Round cutter design with eight incisions, longer service life; 11 teeth 1mm spacing configuration, suitable for 0-60 micron Coating thickness of soft substrate adhesion testing.

$ 866.00

Equipped with 11 teeth 1mm pitch stainless steel cutter head, suitable for 0-50μm film thickness test, adjustable cutter head angle, with nylon brush and 2.5x magnifying glass, to meet a variety of standard requirements.

$ 1119.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.