Coating Color Matching Cabinet

The color matching cabinet simulates standard light source environments to eliminate metamerism. During operation, samples and standard color plates are placed side by side for observation, facilitating on-site color comparison, quality inspection, and color difference control in the supply chain.
Selection
When selecting, it is important to ensure that the light source types cover commonly used standards such as D65 and CWF. The cabinet size should be suitable for the samples being tested, and the interior walls should be neutral gray to avoid interference. Additionally, consider the lifespan of the lamps and the ease of replacement, as well as the availability of a UV light source for detecting fluorescent materials.

Terms

Standards

Instruments

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

With three light source system, color rendering index up to 98, all metal structure with three drawer, table size 1350 * 900mm, in line with ISO3664 international standards.

$ 2365.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

Contains 215 Colors, Fan-shaped design is easy to carry, color sample size 2.0x5.0cm, each page displays 5 Colors, bright type, widely used in Coating industry color comparison.

$ 96.00

With illumination adjustment function, support D65 Illuminant to meet CIE Class A Light spectrum matching, no need to warm up and no flicker, equipped with 45 degree observation station to achieve 45/0 observation conditions, suitable for large items Colorimetric.

$ 4237.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

With three light sources including D65, TL84 and D50, high color strength index CRI = 98, the all-metal material is stable in structure, providing uniform lighting and accurate color evaluation, suitable for a variety of industry environments.

$ 1961.00

Standard light sources covering 6500K to 2700K Color temperature range, support UV detection; no need to warm up and open immediately, low energy consumption without heating; Illuminant use time can be displayed, with 45 ° standard stand optional.

$ 315.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

With four Illuminant automatic switching function, display the use time of each Illuminant, no need to warm up without flashing, Color temperature range covers 2700K to 6500K, low energy consumption without heating, support Metamerism detection.

$ 354.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Flexibility of Elastic Coatings Tested by Cylindrical Mandrel Bend Tester
This article introduces a method for testing the flexibility of elastic coatings using a cylindrical mandrel bending tester. During the test, the coated test panel is bent around cylindrical mandrels of varying diameters to 180 degrees to observe whether the coating cracks or peels off.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.