Reactor glass

Reaction vessel glass is a transparent container resistant to high temperatures and pressures, capable of withstanding chemical reaction conditions through borosilicate materials, facilitating the observation of reaction processes, and is used for laboratory synthesis, material mixing, and process research.
Selection
When selecting a glass reactor, ensure it matches the temperature and pressure range of the reaction, check the purity of the material to avoid interference from impurities, confirm that the interface dimensions are compatible with the equipment, consider corrosion resistance to suit the chemical medium, and evaluate transparency for easy monitoring.

Terms

Standards

Instruments

Glass thickness and air interlayer thickness can be measured at the same time. Glass thickness range is 70mm, air interlayer range is 34mm, light and portable operation is simple.

$ 341.00

Equipped with microwave and ultrasonic synergy function, 2000ml large-capacity reactor and 1800W ultrasonic power, support platinum resistance accurate temperature measurement and magnetic stirring, and realize multi-mode chemical reaction control.

$ 15887.00

Using laser reflection principle to achieve one-sided measurement, accuracy of 0.1mm, can simultaneously obtain multi-layer Glass and air layer Film thickness, support automatic and manual mode, adapt to three glass two Chambers, laminated Glass and other materials.

$ 667.00

Equipped with a 230 × 380 × 6mm Glass face, the adjustable size range is 275 × 205mm to 275 × 255mm. The bakelite base ensures a stable platform and adapts to different experimental needs.

$ 219.00

Glass composite ElectRode and LT Glass sensing film, Measurement range 0-12pH, built-in temperature sensor automatic compensation, small design for micro sample detection, Bluetooth 4.0 technology implementation 10 Meters wireless transmission.

$ 607.00

Glass plate with 440 × 180 × 8mm size is used to ensure uniform film surface, chemical corrosion resistance and easy cleaning and maintenance, providing accurate film evaluation results.

$ 115.00

440 * 355 * 8mm flat Glass substrate is used to ensure film uniformity; chemical corrosion resistant material is easy to clean and maintain, and clip fixed design ensures Spreader Stability.

$ 125.00

The fitting specially designed for hardness Gauges, made of Glass plate, can provide a stable test platform to ensure the accuracy and Repeatability of Hardness measurement results.

$ 74.00

Glass transparent material, size 240 * 160 * 8mm, flat surface to ensure uniform film, chemical corrosion resistance and easy to clean and maintain, clip fixed substrate easy to operate.

$ 102.00

Transparent Glass material ensures uniform film, size 145 * 110 * 8mm provides accurate evaluation results, chemical corrosion resistance and easy cleaning and maintenance, suitable for a variety of Coating performance tests.

$ 99.00

Glass material ensures that the film is flat, used with wire Rod or Film Applicator, the specification size is 110 * 180mm, and the operation is simple and efficient.

$ 106.00

High borosilicate Glass material, corrosion resistance and can withstand large thermal Impact, vacuum negative pressure of 0.095MPa, Speed range 50~ 500rpm, suitable for material synthesis and distillation recovery.

$ 3849.00

Using LT Glass sensing film, built-in temperature sensor, support Bluetooth 4.0 connection, transmission distance of 10 Meters, using CR2032 battery life of about 500 hours, suitable for micro vessel sample measurement.

$ 780.00

Using 160 * 280mm size, with wire Rod scraping ink to ensure that the film is flat, Glass table is conducive to operation and observation effect.

$ 112.00

Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.

$ 444.00

Articles

Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
DSC analyzer measures the glass transition of degradable films.
This article explains how to use a differential scanning calorimeter to measure the glass transition temperature of a degradable film. It first clarifies that the glass transition is the process by which a material changes from a glassy state to a highly elastic state, which appears as a baseline shift on the curve.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The polymer film is formed by blade coating on a glass substrate using a film applicator.
This article introduces the technique of using a film applicator to doctor-blade polymer films onto glass substrates.
Differential scanning calorimetry for determining the glass transition temperature of epoxy resin
Differential scanning calorimetry analyzes the thermal properties of materials by measuring the heat flow difference between the sample and a reference material.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.