Temperature thermal paper

Thermal paper is coated with a thermosensitive layer that undergoes a chemical reaction and changes color when heated. It is used to record temperature changes and is commonly employed for temperature curve recording in ovens and sterilization equipment.
Selection
Select a paper type with a matching range according to the maximum temperature of the equipment, paying attention to the color sensitivity and preservation period, avoiding exposure to light and humid environments, and ensuring compatibility with the thermal head resolution of the printing device.

Terms

Standards

Instruments

Using irreversible discoloration technology to accurately record the highest temperature experienced, 8-grid rectangular temperature points cover the range of 160 ° C to 199 ° C, with oil and water resistance and ISO 9001 standard, accuracy of +/- 1% range.

$ 92.00

Using irreversible discoloration technology, 8 temperature points accurate monitoring, Precision up to +/- 1 ℃, with oil and water resistance, in line with ISO 9001 standard, size 51 * 18mm easy to paste use.

$ 89.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Measurement range 10~ 16000mN, resolution 0.1mN, pneumatic fixture to ensure stable clamping, thermal printer real-time output test data, suitable for a variety of sheet material Tear strength detection.

$ 2066.00

Adopt variable frequency motor control to achieve 50 +/- 5mm/min compression speed, equipped with thermal printer to achieve high-speed silent printing, effective Travel up to 400mm and platen spacing can be arbitrarily set 0-500mm.

$ 1747.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

Temperature resolution is up to 0.1 ℃, heating rate is adjustable from 0.1 ℃ to 20 ℃/min, hot stage method and visual measurement are supported, which is suitable for the study of thermal characteristics of trace samples.

$ 4600.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Using three-box equipment structure, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy reaches +/- 0.5 ℃, and the air circuit switching method realizes fast Thermal Shock, which is suitable for material physical and chemical change testing.

$ 38156.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Using a two-box mobile Impact structure, the air pressure drives the test object to move up and down, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. Equipped with HFC environmentally friendly refrigerant and ultra-low temperature freezing system, the cooling is fast and efficient.

$ 16840.00

Temperature range RT +~ 300 ℃, heating rate 120 ℃/h or 50 ℃/h, maximum deformation Measurement range 1mm, support thermal deformation and Vicat test, real-time display and alarm function.

$ 2010.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.