Oscillating Machine

The shaker drives the sample container through a motor to perform reciprocating or rotational motion, ensuring uniform mixing, dissolution, or acceleration of reactions for the internal substances. It is used in laboratories for color matching and stirring of paints and inks, as well as for dissolution testing of plastic particles. Its amplitude and frequency are adjustable to accommodate the processing needs of samples with different viscosities.
Selection
When selecting, consider the compatibility between sample characteristics and the container, and verify that the oscillation method aligns with the experimental objectives. Check whether the motor power meets the load requirements, and pay attention to operational noise and temperature rise control. Confirm that the clamps are compatible with commonly used flask sizes, and ensure the operation interface is simple and clear. For long-term use, evaluate the durability of the mechanical structure.

Terms

Standards

Instruments

Temperature control accuracy +/- 0.2 ℃, Temperature Uniformity ≤ +/- 0.3 ℃, DC brushless motor drive maintenance-free, with power-off automatic recovery and 0-100 hours timing function, support a variety of module replacement.

$ 908.00

Driven by DC motor, the clamping disc rises and falls rapidly, supports 0-2 hours oscillation time adjustment; with automatic pressure adjustment function to avoid container damage, with 680-710 times/minute Frequency to achieve up and down before and after multi-shake mixing, the main motor Power 750W.

$ 2268.00

With +/- 0.1 ℃ high temperature control accuracy and 0-200rpm Oscillation Frequency, using rotary oscillation and 8-hole design to ensure experimental Temperature uniformity and Sample Handling conformity.

$ 1122.00

Three eccentric axis equilibrate drive to ensure uniform sample oscillation, Speed range 40~ 300rpm, large-screen LCD display multiple sets of data, power-off automatic saving paraMeters, low heat dissipation DC motor supports long-term continuous operation.

$ 2150.00

Stainless steel liner corrosion and easy to clean, PID temperature control accuracy +/- 1 ℃, stepless speed motor noise is low, support multi-stage programming to simplify the test process, Temperature uniformity +/- 1 ℃.

$ 819.00

Using three eccentric axis equilibrate drive to ensure uniform sample oscillation, Speed range 40~ 300rpm, swing amplitude 35mm, support long-term continuous operation, with gentle start and Rotation speed monitoring function, to prevent sample spill and equipment failure.

$ 2447.00

Temperature range RT +~ 50 ℃ +/- 1 ℃, Oscillation Frequency 0~ 300rpm, with reciprocating oscillation and timing function, reasonable structure and easy operation, high stability performance to meet the needs of laboratory thermostatic foster.

$ 587.00

Using three eccentric axis equilibrate drive to ensure uniform sample oscillation, Oscillation Frequency 40~ 300rpm adjustable, swing amplitude 35mm, support long-term continuous operation and Rotation speed monitoring and mild start function.

$ 2939.00

Temperature range 10~ 99 ℃, temperature control accuracy +/- 1 ℃, stainless steel liner anti-corrosion, stepless speed motor low noise, support multi-stage programmable control to simplify the experimental process.

$ 2447.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.