Benchtop GlossMeter

A desktop glossmeter measures the gloss value by illuminating the sample surface with a light source at a fixed angle and calculating the ratio of the specularly reflected light intensity to the reflectivity of a standard plate. It is used to detect the reflective properties of materials such as coatings, plastics, and paper, controlling the appearance quality of products in both production lines and laboratories.
Selection
When selecting, consider the measurement angle (20° is suitable for high-gloss materials, 60° is a general-purpose type, and 85° is used for low-gloss materials). Verify that the instrument complies with ISO/ASTM standards, confirm that the measurement aperture matches the sample curvature, check the calibration certificate of the standard plate, and ensure that the instrument's calibration cycle and stability meet daily testing requirements.

Terms

Standards

Instruments

With 60 ° Measurement Angles and 9 * 15mm Measuring Area, the repeatability is up to +/- 1GU, with automatic check and correction standard board function and 30-second automatic shutdown design, which meets the requirements of JJG696 secondary working Glossmeter.

$ 167.00

With 2x3mm minimum measurement diaMeter, it can measure any curved surface sample; Repeatability up to 0.2GU, using dual optical path technology and high-quality Sensor; Built-in simple and statistical Measurement mode, support Glossiness comparative analysis.

$ 4559.00

Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.

$ 196.00

Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.

$ 196.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Made with precision machining technology, excellent surface Smoothness, suitable for mainstream Glossmeter models, providing stable and reliable calibrated benchmarks, and stable repeability performance.

$ 119.00

Dual angle measurement 20 ° and 60 °, Stability less than +/- 0.4GU/30Min, Repeatability 0.5GU, can store 254 sets of data, portable and lightweight design, Automatic calibration without manual adjustment.

$ 323.00

Using thermal printing technology, it is designed for use with testing instruments. It can directly connect the color difference Meter and Glossmeter to achieve real-time output of measurement data and report generation.

$ 220.00

Using 20 °/60 ° double angle measurement, can automatically calculate the fog shadow value, Repeatability +/- 1.2GU, small size only 380g, super power saving design one battery can measure 100,000 set of data.

$ 759.00

Adopt 1.5x3mm elliptical measurement port, specially designed for concave surface, Measurement accuracy +/- 1.2GU, Stability +/- 0.4GU, compact and portable, suitable for complex shape surfaces.

$ 598.00

Adopt 60 ° standard Measurement Angles, Measurement range 0~ 200GU, Repeatability +/- 1GU, equipped with 3.5-inch high-resolution color display, built-in rechargeable battery to support long-term continuous work.

$ 296.00

Adopt 60 ° Measurement Angles, resolution is 1GU, no need to set zero operation, calibrated by black and white standard board, small size and easy to carry, suitable for long-term measurement in the field.

$ 231.00

Adopt 75 ° Measurement Angles, range 0~ 200Gu, Repeatability 0.2GU; Compact and portable, battery life is nearly 60 hours, support a variety of Measurement modes, quartz crystal standard version has a low annual change rate.

$ 477.00

Adopt 45 ° Measurement Angles, Measurement range 0~ 200Gu, light spot size 9x15mm oval, support automatic, manual, single and average multiple Measurement modes, easy operation and good Stability.

$ 477.00

Using 75 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with rechargeable battery with long service life, suitable for low Gloss object surface measurement.

$ 457.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Haze meter detects haze on high-gloss coating surfaces
Haze is the phenomenon where a high-gloss coating surface causes a blurring of reflected images due to light scattering, which reduces visual clarity. A haze meter quantifies the haze value by measuring the intensity ratio between the specularly reflected light and the scattered light at specific small angles. The lower the value, the clearer the surface.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.