Online CO Monitor

Online carbon monoxide analyzers continuously detect the concentration of carbon monoxide in gases through electrochemical or infrared sensors, converting chemical signals into electrical signals for output. They are used for industrial process monitoring, combustion efficiency management, and environmental safety detection, enabling real-time monitoring of gas emissions in equipment such as boilers and kilns.
Selection
When selecting, consider whether the detection range covers the on-site concentration, if the response speed matches the process requirements, and if the protection rating suits the installation environment. Confirm the sensor's lifespan and maintenance cycle, ensure the output signal is compatible with the existing control system, and refer to industry application cases to verify stability.

Terms

Standards

Instruments

Using Infrared Sensor to monitor CO2 concentration, not affected by Temperature Humidity, CO2 concentration recovered within 5 minutes after opening the door, Temperature Fluctuation +/- 0.2 ℃, equipped with Microbial Filter and door temperature heating system to prevent condensation pollution.

$ 3338.00

Infrared Sensor is used to monitor CO2 concentration, which is not affected by temperature and Humidity, and restores the set CO2 value within 5 minutes after opening the door; Equipped with Microbial Filter, the filtration efficiency of ≥ 0.3 μm particles reaches 99.99%, effectively preventing pollution.

$ 4177.00

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 recovery time ≤ concentration value × 1.2min, built-in ultraviolet sterilization lamp and microbial Filter, effectively prevent foster pollution, the use of antibacterial stainless steel lumen for easy cleaning and maintenance.

$ 1555.00

Using microcomputer module control, CO2 control accuracy of 0.1%, temperature resolution of 0.1 ℃, equipped with CO2 and gas dual filtrate device, liner four corners arc design for easy cleaning.

$ 2400.00

Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 uniformity +/- 0.1%, built-in UV sterilization lamp and microbial Filter, antibacterial stainless steel inner cavity four corners arc design for easy cleaning, support programmatic programming and Linear dispersion display function.

$ 4971.00

Infrared CO2 Sensor Response Fast, Not Affected by Temperature Humidity, CO2 Recovery Time ≤ 3 minutes; Circulating wind speed automatically adjusts to avoid sample volatilization; Door temperature heating prevents condensate pollution.

$ 3402.00

Using infrared CO2 Sensor control accuracy +/- 0.1%, gas sleeve heating heating, CO2 recovery time does not exceed the concentration value × 1.2 minutes, double door structure sealing good anti-pollution.

$ 1524.00

Equipped with infrared CO2 sensor accuracy of 0.1%, with ultraviolet sterilization and door heating anti-condensation design, CO2 recovery time ≤ concentration value × 1.2 minutes, support RS-485 interface connection.

$ 4506.00

Equipped with infrared CO2 sensor accuracy of 0.1%, built-in ultraviolet sterilization lamp can effectively prevent pollution, support 0-20% CO2 concentration range, the use of antibacterial stainless steel cavity for easy cleaning and maintenance.

$ 3901.00

Adopt pre-treatment technology, adapt to high temperature, humidity and dust environment, equipped with 7-inch Touchscreen real-time display concentration Linear dispersion, detection error ≤ +/- 3% F.S, support 4-20mA and RS485 output, can realize automatic drainage and zero emission cycle function.

$ 1493.00

Using Infrared CO2 Sensor, restore 5% concentration within 3 minutes after opening the door; Equipped with 90 ℃ heating and humidity sterilizing system, effectively eliminate microbial pollution; Temperature Fluctuation +/- 0.1 ℃, CO2 control accuracy +/- 0.1%.

$ 6505.00

The infrared CO2 sensor accuracy is +/- 0.1%, which is not affected by temperature Humidity; the circulating fan speed is automatically adjusted to avoid sample volatilization; the door temperature heating system prevents condensate pollution; the CO2 recovery time is ≤ 3 minutes, and the temperature recovery is ≤ 8 minutes.

$ 1835.00

The cavity preheating technology implementation +/- 0.8 ℃ Temperature Uniformity, equipped with infrared CO2 Sensor to ensure accurate concentration, standard ultraviolet sterilizing lamp to prevent cross-contamination, support remote monitoring function.

$ 4161.00