Vertical Dispersing Mixer

The vertical dispersion mixer uses a motor to drive the rotating shaft, which in turn rotates the serrated dispersion disc at high speed, generating shear force to break down and mix materials. It is used for the dispersion and homogenization of solid particles in liquids in industries such as coatings and inks. It is suitable for processes such as pigment pre-dispersion and slurry preparation.
Selection
When selecting, consider matching the material viscosity with the motor power, and determine the tank capacity based on the processing volume. The dispersion disc material should be corrosion-resistant, and the speed range should cover medium to high-speed requirements. Pay attention to the shaft seal structure to prevent leakage, and ensure the stirring shaft length is compatible with the container depth.

Terms

Standards

Instruments

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

Adopt closed system design, mixing capacity 5-200G, Speed range 1500-3500rpm, can achieve fast and efficient Mix & disperse, the operation process is quiet, pollution-free and bubble-free, support manual and intelligent two control modes.

$ 6851.00

The device can quickly mix ground dispersed materials in a closed system, with a speed range of 1500-3500 rpm, a mixing capacity of 5-150G, and features bubble-free and quiet operation.

$ 6205.00

The equipment supports 0.5-20 liters of barrel paint mixing, revolution speed 100-200rpm, rotation speed 200-400rpm, using multi-stage intelligent frequency conversion speed regulation and door opening and shutdown protection to achieve smooth operation and safe operation.

$ 2575.00

The fixture can fix the upper and lower ends of the butterfly specimen into a vertical shape, test the vertical compression strength, suitable for a variety of Corrugated Board types, Dimension 150 * 105 * 65mm, weight about 2Kg, easy to operate.

$ 596.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Adopting a planetary two-way swirl/spin structure, the mixing arm runs in reverse with the basket to achieve rapid mixing, with a maximum load of 300g and a speed range of 400-2800rpm. The equilibrate is quiet and can be operated directly in the syringe or test bottle.

$ 5237.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Support forward and reverse rewinding and unwinding functions, with tension control and deviation correction functions, vertical mesh running speed 1mm/s to 1m/min, effective coating area 1500 * 600mm, to ensure that the mesh vertical stability without shaking.

$ 14274.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Adopt biaxial planetary motion structure, revolution 0-70rpm and rotation 0-80rpm adjustable, equipped with automatic wall scraping device to achieve no dead point mixing, Total Power 6.75kw to meet a variety of material handling needs.

$ 7303.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.
The impact of the disperser impeller structure on dispersion effectiveness.
This article mainly discusses how the impeller structure of a disperser affects the dispersion effectiveness. The impeller is the core component of a disperser, and its design directly influences the uniformity and stability of the final mixture.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.