Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.
Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.
Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.
Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.
Adopt magnetic thickness measurement method, measurement range 0-1250μm, error +/- 3%, with continuous and single measurement mode, can store 1560 measurement data, support a variety of calibrating methods.
Measurement principle using magnetic method, thickness range 0-3000μm, error +/- 3%, with split Probe structure, support single and continuous Measurement mode, equipped with RS-232C interface.
Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.
Measuring methods of magnetic Induction and eddy Current, covering 0-1500 μm range, resolution up to 0.1 μm, support continuous and single Measurement mode, statistical function and 500 sets of data storage, suitable for different curvature radii and substrate Film thickness scenes.
Adopting the principle of magnetic thickness measurement, the range can reach 13000 μm, the error range is +/- 3%, with two methods of continuous measurement and single measurement, supporting large-capacity storage and upper and lower limit alarm functions, and the wear-resistant alloy probe is sturdy and durable.
Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.
Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.
Hardness and corrosion resistance, wet film thickness adjustment range 0-4500 μ m, magnetic suction design for quick replacement and cleaning, differential head accuracy of +/- 2 μ m to ensure film uniformity.