Pigment Drying Oven

The pigment drying oven quickly dries or cures samples such as coatings and inks at set temperatures by heating and circulating air. It is used to test the heat resistance, stability, and drying time of pigments, commonly found in laboratory quality control and product development processes.
Selection
When selecting a pigment drying oven, considerations should include the temperature range and uniformity, the capacity and size to match the sample volume, and temperature control accuracy to meet standard requirements. Attention should also be paid to the heating method and material durability, while configuring the equipment based on the frequency of daily testing tasks and available space conditions.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Adopt single chip microcomputer automatic control, grinding disc diaMeter 220mm, load weight up to 2.92kg, compact structure, easy assembly and disassembly, suitable for pigment physical performance inspection.

$ 1106.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Air disturbance technology is used to simulate indoor air flow, equipped with 24 independent sample Chambers to prevent cross-contamination, the drying Temperature range is adjustable at RT-50 ° C, and the outer exhaust air is purified without affecting the environment.

$ 3173.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Shelf direct heating technology, each Shelf independent temperature control, Temperature Fluctuation +/- 1 ℃, heating time is shortened by more than 50%, to ensure that the drying process without oxidation, accurate and stable measurement.

$ 13294.00

Temperature uniformity is improved by air circulation system, temperature control accuracy is +/- 0.5 ℃, Temperature resolution is 0.1 ℃, mirror stainless steel liner ensures durability and easy cleaning, suitable for a variety of drying applications.

$ 435.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Blue-style grinder achieves efficient grinding of ink fineness.
The basket mill is a type of wet grinding equipment used in fine chemical fields such as ink production. It utilizes a high-speed rotating impeller to drive grinding media, generating shear and impact forces on the slurry, thereby dispersing pigment particles and reducing their fineness.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Comparison of Pigment Fineness Dispersion between Flat Grinding Mill and Sand Mill
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Whiteness meter measures the whiteness of white pigments
This article introduces the standard method for measuring the whiteness of white pigments using a whiteness meter. Whiteness is an important optical indicator for evaluating the quality of white pigments, and a whiteness meter can provide objective measurements.
The effect of a flat grinder on the preparation of color paste's tinting strength
This article primarily explores the impact of process parameters on tinting strength during the preparation of color pastes using a flat grinding machine. Tinting strength is a core performance indicator of color pastes, reflecting the coloring efficiency of pigments within the system.