Metal Constant Temperature and Humidity Test Chamber

The metal constant temperature and humidity test chamber precisely controls the temperature and humidity environment within a sealed space through heating and cooling systems as well as humidification and dehumidification devices. It is used to simulate the performance changes of products under specific temperature and humidity conditions, commonly applied in the weathering tests and quality verification processes of electronic components and material samples.
Selection
When selecting, it is essential to match the temperature and humidity range and control accuracy required by the test standards, and consider the compatibility of the chamber volume with the sample size. Pay attention to indicators such as temperature uniformity and fluctuation, and confirm the sensor calibration cycle. Inspect the corrosion resistance of the chamber material and its sealing performance to ensure long-term operational stability.

Terms

Standards

Instruments

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.

$ 1414.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.

$ 1627.00

Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.

$ 4122.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.

$ 3630.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.

$ 4663.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Temperature resolution up to 0.1 ℃, Humidity Control Range 60~ 85% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure experimental safety.

$ 2347.00

Using imported Sensor and TMHM equilibrating Conditioning method, temperature control accuracy of +/- 0.5 ℃, humidity control accuracy of +/- 3% RH, with independent temperature limit alarm system to ensure experimental safety.

$ 3531.00

Fluorine-free design, Temperature range -40~ 85 ℃, Humidity control 45~ 95% RH, mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safe operation.

$ 4843.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.