Ballast Tank coating Gloss Meter

The ballast water tank coating gloss meter measures the ratio of the specular reflection intensity of the coating surface to the reflectivity of a standard plate by illuminating the surface with a light source at a fixed angle. It is used to monitor the gloss uniformity of anti-corrosion coatings in ballast tanks, ensuring that the coating application quality meets ship protection standards.
Selection
When selecting, consider the ballast water tank testing environment and opt for instruments with explosion-proof structures. The measurement angle should be chosen based on the gloss range of the coating, with 20° for high gloss and 60° for matte finishes. The instrument must feature data storage and corrosion resistance, and the calibration plate should come with a traceability certificate.

Terms

Standards

Instruments

Using 60 ° Measurement Angles and 0~ 199.9GU Measurement range, with 10 * 20mm Measuring Area and +/- 1.2GU Indication Error, the whole set of instruments is designed in one piece and the measuring port has anti-scratch coating.

$ 364.00

The equipment has a 15-liter large-capacity water Tank and an 8mm inner diaMeter water pipe, supports 0 to 99 hours of time control, adopts stainless steel structure and automatic control device, and is suitable for coating stain resistance testing.

$ 369.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

The pumping rate is up to 4L/s, and the noise value is only 68dB. The gas ballast valve design is adopted to prevent the pump oil from mixing and prolong the service life. It is compact and easy to install, and supports a variety of interface conversions.

$ 361.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Adopt 45 ° circular lighting structure, reduce texture effect, compatible with 60 ° Gloss measurement, Repeatability Delta E * ab 0.03, built-in high Sensitivity Sensor, suitable for matte and textured material surfaces.

$ 6334.00

The three-angle measurement design covers 20 °/60 °/85 °, the measurement range is 0.1~ 200GU, the repeability is +/- 0.5GU, and 254 sets of data storage and Bluetooth output are supported to meet the needs of surface Gloss detection of various materials.

$ 336.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 1000GU, Repeatability 0.2GU, support USB and Bluetooth interface, can store 10000 sample data, suitable for surface Gloss measurement of various materials.

$ 332.00

Using 60 ° Measurement Angles and 0~ 199GU range, Repeatability 1GU, single AA battery can work for more than 58 hours, small size and anti-scratch coating to protect the surface of the tested object.

$ 286.00

45 ° ring illumination and 0 ° viewing angle structure are used to effectively eliminate mirror light interference on textured surfaces. Built-in Gloss Sensor realizes simultaneous measurement, and the spectral reflectance Repeatability Standard Deviation is within 0.08%, suitable for matte and textured materials.

$ 3753.00

Temperature control range -10~ 95 ℃, accuracy up to +/- 0.05 ℃, equipped with 6L/min circulating pump to ensure uniform temperature, Tank volume 7.5L to meet the needs of multi-sample testing.

$ 1429.00

Using 60 ° Measurement Angles, Measurement range 0~ 120GU, anti-scratch coating treatment of the measuring port to protect the tested object, a single AA battery can last for more than 58 hours, small size and easy to carry.

$ 412.00

Measurement beam of light diaMeter 1.5mm, measurement window 4mmx2mm, suitable for facet and small curvature surface measurement, low energy consumption single battery can last for more than 58 hours.

$ 428.00

60 ° projection angle, Measurement range 0~ 3000GU, measurement error less than 2GU, compact and easy to carry, accurate and stable measurement, to meet the requirements of ISO and GB standards.

$ 328.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.