Filler scraper fineness Gauge

The filler scraper fineness gauge measures the dispersion fineness of fillers or pigment particles in coatings and inks by using a scaled wedge-shaped groove and a scraper to spread the sample into a thin film, and observing the scale value corresponding to the position where particles appear. It is used for production quality control to ensure product uniformity.

Instruments

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-250μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1531.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-15μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-100μm, suitable for particle size and fineness of grinding inspection, ergonomic design for easy grip.

$ 1157.00

Made of stainless steel, with a range of 50 to 150 μm and a Graduation of 10 μm, the plane finish of the scraper is up to 10 grades, suitable for accurate determination of particle fineness in the Coating and inks industries.

$ 138.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-25μm, ergonomic design, easy to hold, suitable for particle size and fineness of grinding detection.

$ 1157.00

Made of Hardness 52 +/- 2HRC wear and corrosion resistant alloy steel with 0-100μm range and 5μm Graduation, the single-channe design meets several international standards for a wide range of material particle Fineness measurement.

$ 172.00

Double groove design can achieve rapid fineness detection, Measurement range 0~ 100μm, accuracy +/- 2 microns, wear-resistant and anti-corrosion stainless steel material, suitable for a variety of material fineness determination.

$ 1086.00

The scraping speed is adjustable from 10-100mm/s, and the drawdown blade load 1.75-6 kg is adjustable. It is used with High Accuracy GrindoMeter to avoid personnel operation errors and improve test conformity.

$ 1364.00

Measurement accuracy of +/- 2 microns, wear resistance and corrosion resistance, handheld operation, suitable for rapid detection of various material fineness.

$ 1086.00

Stainless steel is more durable, with a length of 75mm, suitable for all models of GrindoMeter, and meets ASTM D1210, DIN 53203 and other standards to ensure accurate fineness measurement.

$ 549.00

Made of stainless steel, the range is 0-100μm, Graduation is 5μm, and the plane flatness of the scraper is 0.003mm to ensure accurate and reliable particle fineness measurement.

$ 138.00

Tool steel hardened and polished, accuracy +/- 2μm, range 0-50μm, ergonomic design for easy holding, suitable for particle size and fineness of grinding inspection.

$ 1157.00

Made of Swiss tool steel, Abrasion Resistance and corrosion resistance are excellent, accuracy reaches +/- 2 microns, wide groove design is easy to handle, suitable for a variety of material fineness detection.

$ 1323.00

Double groove structure can be measured twice at the same time, Measurement range 0~ 25μm, accuracy +/- 2μm, hardened stainless steel material wear and corrosion resistance, suitable for a variety of material fineness detection.

$ 1086.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Muffle Furnace Ash Test Method for Determination of Inorganic Filler Residues in Varnish
This article introduces the method of using the muffle furnace ash test to determine the residual amount of inorganic fillers in varnish. The inorganic substances in varnish can affect the performance of the coating, making accurate determination of ash content important for quality control.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
The Invisible Impact of Abnormal Resistivity on the Performance of Specialty Papers
This article discusses the impact of resistivity on the performance of specialty paper. Resistivity reflects the conductivity of the paper, and its abnormal fluctuations may be caused by factors such as changes in raw material ratios, fillers, or the production environment.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
An article tells you how to choose a fineness gauge.
This article introduces how to select and use a grind gauge. It is a tool for measuring particle size in coatings and inks. When selecting one, the first step is to choose the appropriate range based on the estimated fineness of the sample (commonly 0-50 µm or 0-100 µm).