Digital Well Digestion Furnace

The digital display well-type digestion furnace uses electric heating to facilitate the reaction between samples and acid in a sealed well-type chamber, decomposing organic matter into inorganic substances. It is employed for sample pretreatment to facilitate subsequent elemental detection. This equipment is applied in industries such as food, environmental monitoring, and chemical engineering for detecting indicators like heavy metals.
Selection
Select the heating power and temperature control range based on the sample characteristics. Consider matching the sample processing capacity with the furnace chamber capacity. Pay attention to temperature control accuracy and uniformity. Check for corrosion-resistant materials and safety protection design. Choose functional configurations in combination with daily testing requirements.

Terms

Instruments

Glass testtube with bubble well structure, length 100mm, diaMeter 27mm, capacity 8 square centiMeters, suitable for a variety of PolariMeter types.

$ 119.00

Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Glass shell structure with bubble well design, testtube length 200mm, diaMeter 27mm, capacity of 15 square centiMeters, to ensure the accuracy of Optical inspection measurement and ease of operation.

$ 119.00

Heat and corrosion resistant material, can digest 25 samples at the same time, Temperature Stability up to +/- 0.5 ℃, support 0-180 minutes timing and continuous digestion, with overheating protection and temperature alarm function.

$ 2302.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.

Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.

It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.

$ 1927.00

Adopt digestion Colorimetric integrated tube design, detection limit of 0.02mg/L, support 125 ℃ closed digestion, built-in imported cold light source life of 100,000 hours, can store 4000 sets of data and support multi-mode power supply.

$ 2203.00

Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.

$ 1355.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

The instrument adopts PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure consistent digestion of the same batch of samples, equipped with abnormal alarm and double-decked insulation system.

$ 1219.00

Using sealing catalytic digestion and Colorimetry measurement, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, and the batch processing of 12 water samples is supported, and the operation is simple and time-saving.

$ 1114.00

The separate design of digestion and determination does not affect the accuracy, COD digestion is completed in 15 minutes, 30 standard Linear dispersion and 199 sets of data can be saved, 4-16 water sample batches are supported, and IP65 waterproof and dustproof design is adopted.

$ 1366.00