Waterproof Analytical Balance

The waterproof analytical balance features a sealed structure and corrosion-resistant materials to prevent liquids and dust from entering the weighing system. With a built-in humidity sensor and automatic calibration function, it maintains weighing accuracy in humid or chemical environments. It is suitable for applications requiring moisture and corrosion resistance, such as solvent weighing in laboratories and moisture-sensitive material testing in industrial settings.
Selection
When selecting, pay attention to the IP rating, with IP67 capable of handling spray environments. Consider the weighing range and accuracy to match experimental needs, and opt for a stainless steel weighing pan for corrosion resistance and easy cleaning. Check if it offers four-level anti-static functionality to prevent powder adhesion. Ensure the balance supports on-site calibration to adapt to environments with temperature and humidity fluctuations.

Terms

Standards

Instruments

With 150kg weighing range and 5g Readability, waterproof cover design and large screen backlit LCD display, AC and DC dual-use to adapt to different working environments.

$ 783.00

With 60kg weighing range and 2g Readability, stainless steel housing and waterproof cover design, large screen backlit LCD display ensures clear readings and adapts to humid environments.

$ 719.00

With 300kg weighing range and 10g Readability, it adopts stainless steel scale body structure and is equipped with peripheral waterproof cover to ensure stable operation in humid environment and easy cleaning and maintenance.

$ 827.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow star pan design, effectively reduce airflow and static interference, improve weighing accuracy and Stability.

$ 2171.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

With waterproof and moisture-proof characteristics, weighing range 30kg, accuracy 1g, stainless steel scale body structure, suitable for humid environment, to ensure stable and reliable weighing.

$ 653.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow pan design, effectively reduce airflow and static interference, improve weighing Stability.

$ 1848.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

Using electromagnetic force equilibrating Sensor, automatic timing internal calibrating to ensure accuracy, equipped with negative LCD screen, anti-static Glass and hollow star pan to improve weighing accuracy and Stability, support a variety of communication and printing functions.

$ 2494.00

With 15kg maximum range and 0.2g readability accuracy, IP68 waterproof structure and self-drainage design, built-in weight check alarm function, support RS232 and Bluetooth connection, to meet the needs of various harsh environments.

$ 483.00

With 3kg maximum range and 0.1g readability accuracy, IP68 waterproof design and self-drainage structure, support double-sided LED display and built-in weight check alarm function to meet the needs of various harsh environments.

$ 419.00

With automatic dual range double accuracy function, accuracy 0.2mg, seven shock filter adjustable, support a variety of weighing modes such as density direct reading and dynamic weighing, to ensure fast and stable measurement.

$ 448.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Superhydrophobic surface coating is applied to the microstructure substrate using a film coating machine.
This article introduces the coating process of superhydrophobic surface coatings on microstructured substrates. Superhydrophobic coatings feature high water contact angles and low rolling angles, making them widely used in applications such as anti-fouling and waterproofing.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.