High Temperature Furnace Temperature Profiler

The high-temperature furnace temperature curve instrument collects real-time temperature data inside the furnace through thermocouples and records the curve of temperature changes over time during the heating process. It is used to monitor the actual temperature distribution in processes such as baking and curing, helping to adjust furnace temperature parameters and verify process stability in applications like paint curing, printing drying, and plastic heat treatment.
Selection
When selecting, ensure that the temperature measurement range covers the process requirements, the number of thermocouples matches the monitoring points, and the sampling rate adapts to the speed of temperature changes. Pay attention to the compatibility of the thermocouple's temperature resistance rating with the furnace environment, the equipment's protection rating meeting the on-site conditions, and the software functions satisfying the needs for data recording and analysis.

Terms

Standards

Instruments

Measurement range -200 to 1370 ℃, using nano aerospace environmental insulation material, can operate stably in high temperature environment and record temperature data, support a variety of sampling rate selection.

$ 1669.00

With 9-channel temperature measurement capability, Measurement range covering -200 to 1370 ℃, using nano-aerospace environmentally friendly heat insulation material, support multi-directional temperature Linear dispersion tracking and Data analysis optimization process.

$ 2157.00

With 9-channel K Probe, Sampling rate of 0.05 seconds, Measurement range -200 to 1370 ℃, superior thermal insulation performance, can track and monitor Furnace temperature and pRoduct temperature throughout the process in harsh thermal environments.

$ 1669.00

With 6-channel temperature recording capability, thermal insulation performance can reach 400 ° C for 60 minutes, Measurement range -200-1370 ° C, accuracy +/- 0.3 ° C, using nano-aerospace environmentally friendly thermal insulation materials, support multi-directional temperature Linear dispersion tracking mapping.

$ 1305.00

6 channel temperature recording, 700 ℃ environment can work for 90 minutes, using nano aerospace environmental protection insulation material, support 1-30 seconds adjustable Sampling rate, real-time tracking Furnace temperature Linear dispersion, to ensure the stability of the brazing mass.

$ 3372.00

With 8-channel High Accuracy Temperature Measurement, accuracy of +/- 0.3 ℃, using nano-aerospace environmentally friendly heat insulation material, can work continuously for 60 minutes in 200 ℃ environment, support multi-rate sampling and long-term data recording.

$ 1937.00

The six-channel design supports multi-position simultaneous temperature measurement, Sampling rate of 0.05 seconds, with 512M memory can store 16 consecutive test data, and the heat insulation box works stably for 10 minutes in a 280 ° C environment to ensure the accuracy of high temperature scene data.

$ 1427.00

Four-channel K-type Thermocouple configuration, accuracy of 0.5%, insulation performance maintained at 400 ℃ for 60 minutes, support multi-rate sampling and data synchronization analysis, to ensure stable and reliable temperature mapping.

$ 940.00

Four-channel K-type Thermocouple with 0.5% accuracy, the insulation box can work continuously for 1 hour in a 300 degree environment, supports multi-rate sampling and 16000 Data storage, Stability is high and easy to operate.

$ 624.00

Four-channel configuration with K-type Thermocouple, the sampling rate can be adjusted from 1 second to 1 minute, and the thermal insulation performance can last for 60 minutes in a 500 ° C environment to achieve full temperature tracking monitoring.

$ 1014.00

8-Channel design supports multi-point simultaneous temperature measurement, using nano-space insulation material to ensure stable operation at 300 ℃ environment for 60 minutes, equipped with K-type Thermocouple to achieve +/- 0.3 ℃ High Accuracy measurement, suitable for high temperature process monitoring.

$ 1390.00

Equipped with 6 measurement channels and K-type Thermocouple, supports a wide temperature range of 0-1200 ° C, uses 3.5-inch full-color Touchscreen operation, built-in rechargeable battery can work continuously for 4 hours, storage capacity up to 250,000 measurement points.

$ 7458.00

6-Channel design supports multi-directional temperature monitoring, can work for 60 minutes in a 500 ° C environment, using nano-aerospace environmentally friendly heat insulation materials, K-type Thermocouple ensures +/- 0.3 ° C High Accuracy measurement, effectively solving color difference and curing problems.

$ 1451.00

6 channel design with nano space insulation material, can work for 60 minutes in 300 ℃ environment, accuracy of +/- 0.3 ℃, support 200,000 data recording, to achieve high temperature environment stable temperature measurement.

$ 1184.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.