Ultrasonic Constant Temperature Circulating Bath

The ultrasonic constant temperature circulation bath generates cavitation effects through ultrasonic vibration, combined with a constant temperature circulation system to maintain stable temperature. It is used for sample dispersion, degassing, extraction, and constant temperature reactions in laboratories, commonly found in the fields of materials and chemical engineering.
Selection
When selecting, consider matching the tank capacity with the sample volume, ensuring the temperature range covers experimental needs, the ultrasonic power adapts to the material characteristics being processed, the material's corrosion resistance corresponds to the reagent type, and the circulation flow rate meets heat transfer efficiency requirements.

Terms

Standards

Instruments

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet the needs of complex experiments.

$ 12820.00

Imported stainless steel plate and circulating pump, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature range RT + 5~ 95 ℃, with anti-dry burning function, to ensure the safety and stability of the experiment.

$ 356.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface.

$ 3226.00

Adopt non-heat centrifugal circulating pump to avoid self-heating affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control or magnetic stirring function to enhance application flexibility.

$ 1079.00

Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and magnetic stirring system to enhance experimental flexibility.

$ 1093.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, support external circulation function and Flow rate 13L/min.

$ 1237.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1317.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity +/- 0.05 ℃, equipped with multi-level Safety protection device, optional program temperature control and Communication interface, to achieve accurate and stable temperature control.

$ 5173.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.

$ 1794.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 995.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level anti-dry burning and Compressor overload protection.

$ 6857.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices such as low water level anti-dry burning to ensure safe and reliable operation.

$ 1327.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to enhance experimental flexibility.

$ 1622.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection such as power failure and low water level alarm to ensure stable and reliable experiments.

$ 3909.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.