In-Line ColoriMeter

The process colorimeter calculates chromaticity coordinates and color difference values by measuring the tristimulus values of light reflected from the surface of an object. It is used for online monitoring of color consistency during production and is commonly employed in quality control on assembly lines in industries such as coatings, plastics, and printing.
Selection
When selecting a colorimeter, considerations should include measurement accuracy, repeatability, environmental adaptability, compatibility with the materials being measured, data interface compatibility, ease of operation, and maintenance costs to ensure it meets specific production conditions and testing requirements.

Terms

Standards

Instruments

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

Using 100LPI line number and quadrilateral pyramid hole structure, the transfer uniformity of inks is precisely regulated through hole shape and line number, which affects the wet film thickness and ensures the stability of ink supply.

$ 167.00

Using 8mm measurement aperture and photodiode array Sensor, Measurement time is only 1.0 seconds, Repeatability Delta E * ab < 0.08, vertical structure is convenient for pRoduction line inspection and mobile use.

$ 393.00

Using D/8 lighting system, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration technology to ensure measurement accuracy, lithium battery supports 12,000 consecutive tests.

$ 202.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.1ppm. With ultra-high waterproof design, provide replaceable in-line module Sensor, support two-level triple alarm function, compact and portable.

$ 202.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Using 150mm integrating sphere and 25mm test hole, Measurement accuracy Delta R457 ≤ 0.5, support Opacity, transparency and inks absorption value and other Multi-ParaMeter detection, suitable for a variety of sample thicknesses.

$ 2329.00

With +/- 1000mV wide range measurement and manual two-point Adjustment, support automatic diagnosis ElectRode status and fail-safe alarm system, effectively prevent signal interruption problems.

$ 1316.00

Measurement range 0~ 1500μm, accuracy +/- (5μm + 5%), stylus end angle of 60 degrees, suitable for surface profile measurement, with line design for easy connection.

$ 774.00

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Built-in temperature sensor, no need to add reference fluid, PTFE liquid junction and 3/4NPT thread design, Cable length is 5 Meters.

$ 140.00

It has a multi-function smart button design, supports more than 30 Color indicators and 28 kinds of observation Illuminants, adopts non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 is less than 0.2, high measurement Stability, portable and lightweight only 88 grams.

$ 267.00

Adopting quadrilateral pyramid mesh structure, line number 300LPI, print width 70mm, chrome plating on the surface to enhance Abrasion Resistance and block solvent corrosion, electronic engraving technology to ensure accuracy.

$ 167.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Differential Scanning Calorimetry measures the heat of curing reaction of thermosetting polymers.
Differential scanning calorimetry is a commonly used technique for studying the curing reactions of thermosetting polymers. It measures the heat released by a sample during heating to obtain key parameters such as reaction enthalpy and curing temperature.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Differential Scanning Calorimetry for Measuring Compatibility of Plastic Blends
Differential scanning calorimetry assesses the compatibility of plastic blends by measuring the heat flow changes during heating or cooling processes.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.