High Temperature Humidity Chamber

The high-temperature humidity chamber generates a set temperature and humidity environment through electric heating and humidifiers. It is used to simulate the performance changes of products under hot and humid conditions, commonly applied in material weathering tests, electronic component aging tests, and stability assessments of chemical products.
Selection
When selecting, it is necessary to match the temperature and humidity range and accuracy required by the test standards, consider whether the chamber volume can accommodate the samples, pay attention to uniformity indicators, check the ease of operation of the control system, confirm safety protection functions, and refer to energy consumption and maintenance costs.

Terms

Standards

Instruments

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.

$ 5576.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Temperature range -60~ 150 ℃, humidity control range 20~ 98% R.H., with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring, to meet the needs of complex environment testing.

$ 6125.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring, suitable for complex environment simulation test.

$ 7319.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.

$ 7287.00

With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.

$ 5043.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.