Temperature Measuring Device

Temperature measuring devices sense the temperature of objects through thermocouples or infrared sensors, converting physical signals into electrical signals to display numerical values. They are used to monitor the heating and cooling of materials and the operational status of equipment during production processes, commonly employed in temperature measurement scenarios such as ovens and calenders.
Selection
When selecting a temperature measuring instrument, it is essential to clarify the measurement range and accuracy requirements, and consider whether to use contact or non-contact measurement methods. Pay attention to the sensor's response speed and environmental adaptability, check the protection rating and calibration certificate, and ensure compatibility with existing equipment interfaces.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.

$ 6563.00

Temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision stable temperature control, to meet a variety of standard test requirements.

$ 3338.00

Temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision temperature control, to meet a variety of industrial standard testing needs.

$ 4924.00

Using irreversible color change, it features 60°C and 80°C temperature monitoring, rectangular temperature grid design, and reflective display for easy detection of temperature anomalies at night.

$ 80.00

Built-in PT100 temperature sensor, temperature range 0~ 405 ℃, stainless steel shell, suitable for high temperature liquid temperature measurement, real-time accurate monitoring.

$ 106.00

Temperature range -80~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using a unique equilibrating temperature control method to achieve high-precision stable temperature control to meet a variety of testing needs.

$ 14183.00

Built-in 10K temperature resistor, temperature range 0~ 105 ℃, stainless steel shell and temperature sensing components, real-time accurate monitoring of temperature changes.

$ 106.00

Temperature range -20~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision stable control, the main components are imported parts, good reliability.

$ 4813.00

Temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using a unique equilibrating temperature control method to achieve high-precision stable control, the main components imported to ensure reliability.

$ 3943.00

With irreversible discoloration characteristics, Measuring temperature 90 ℃, Dimensions 25 * 40mm, white to black display over temperature, reflective function is convenient for day and night inspection to find temperature anomalies.

$ 80.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -60~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, 304 stainless steel studio to ensure long-term stable operation.

$ 5132.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision temperature control, the studio is made of 304 stainless steel.

$ 6575.00

Temperature sensitive discoloration paint after overheating Color from white to transparent, discoloration effect depends on the object surface Color, Measuring temperature 55 ℃, suitable for rough oil surface use.

$ 131.00

Temperature range -40~ 100 ℃, Temperature Uniformity +/- 0.05 ℃, using non-heat centrifugal circulation pump and U-shaped return circulation design, to ensure that the temperature field is highly uniform, support multi-stage program control.

$ 3404.00

Temperature range -20~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision stable control, the main components imported to ensure reliability.

$ 5055.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.