Immersion Viscosity Cup

Immersion viscosity cups measure viscosity by timing how long it takes for a fluid to completely drain through a small hole at the bottom of the cup. The longer the outflow time, the higher the viscosity. They are used for on-site, rapid viscosity testing of liquid materials such as coatings and inks, offering simple and convenient operation.
Selection
When selecting an immersion viscosity cup, consider the viscosity range of the fluid to be measured and match it with the corresponding cup number. Pay attention to the corrosion resistance of the cup material; stainless steel is suitable for most liquids. Check the precision of the orifice size to ensure the outflow time falls within the specified range. Verify the temperature impact, as some models come with temperature correction features.

Terms

Instruments

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Designed for easy immersion measurement with one hand operation, the 8mm filter diaMeter covers a specific viscosity range, and the aluminum alloy and stainless steel construction ensures durability and accurate flow time determination.

$ 388.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Using aluminum alloy material, filter diaMeter 4mm, viscosity measurement range 34-135cSt, in line with international standards design, hand-held immersion operation is simple, suitable for laboratory accurate measurement.

$ 432.00

Measurement range covers common Coating viscosities with 3mm filter diaMeter, immersion design supports one-handed operation, aluminum alloy ensures durability and meets DIN 53211 requirements.

$ 381.00

Measurement range 400-1800cSt, equipped with 44ml Cup volume, correction factor 0.95-1, accurate viscosity test at 25 ℃ thermostatic environment.

$ 131.00

One-handed operation design is convenient for immersion measurement, 4mm filter diaMeter corresponds to 25-150 seconds outflow time, titanium anodic oxidation aluminum material ensures durability, temperature fluctuations need to be controlled within +/- 0.2 ℃ to ensure Precision.

$ 375.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

Using 4mm stainless steel nozzle design, Measurement accuracy up to 34~ 135cSt viscosity range, anti-oxidation material to ensure long-term stable use, Handheld structure for easy operation.

$ 580.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

The stainless steel material is resistant to oxidation and durable, the filter diaMeter is 4mm, and the measurement flow time is 30 to 100 seconds. It is suitable for various liquid viscosity tests and can be converted to obtain dynamic viscosity values.

$ 580.00

3Mm stainless steel filter design, viscosity measurement range of 7-42cst, flow time of 30-100 seconds, in line with international standards dimensional tolerance, equipped with a unique serial number to ensure measurement accuracy.

$ 436.00

Made of titanium anodic oxidation aluminum and stainless steel, the flow hole diaMeter is 6mm, the capacity is 100ml, and the one-hand immersion measurement meets the DIN 53211 standard to ensure High Accuracy Viscosity Testing.

$ 381.00

Made of stainless steel, aperture 3.76mm, Measurement range 100~ 800cSt, correction factor 0.95~ 1.05, in line with ASTM D4212 standard, suitable for Newton type liquid viscosity test.

$ 131.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.