Mechatronic Analytical Balance

The mechatronic analytical balance combines the lever principle with electromagnetic force compensation technology, converting the mass of a sample into an electrical signal via a sensor for display. It is used in laboratories to weigh small mass samples such as powders and liquids, and is applied in the coatings and inks industry for testing raw material ratios.
Selection
When selecting, focus on a weighing range that covers common sample weights, with reading accuracy meeting detection requirements, and calibration functions ensuring data accuracy. Consider the impact of environmental vibrations and airflow; the balance material should be corrosion-resistant. Pre-heat and stabilize before use, and regularly verify with standard weights.

Terms

Standards

Instruments

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow star pan design, effectively reduce airflow and static interference, improve weighing accuracy and Stability.

$ 2171.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow pan design, effectively reduce airflow and static interference, improve weighing Stability.

$ 1848.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

Using electromagnetic force equilibrating Sensor, automatic timing internal calibrating to ensure accuracy, equipped with negative LCD screen, anti-static Glass and hollow star pan to improve weighing accuracy and Stability, support a variety of communication and printing functions.

$ 2494.00

With automatic dual range double accuracy function, accuracy 0.2mg, seven shock filter adjustable, support a variety of weighing modes such as density direct reading and dynamic weighing, to ensure fast and stable measurement.

$ 448.00

With 0.001g-0.1g accuracy and automatic dual range function, the metal shell is sturdy and durable, and the six-stage shock-proof filter is adjustable. It supports a variety of weighing modes such as density direct reading and dynamic weighing to ensure fast and stable measurement.

$ 357.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy data connection.

$ 425.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for data output.

$ 485.00

Measurement range up to 320μm, support Multi-ParaMeter such as Ra, Rz, etc., with automatic range switching and real-time waveform display function, Continuous Operating Time over 20 hours.

$ 835.00

With 0.01g Readability and 200g weighing range, support counting function and unit conversion, AC and DC dual-use design is easy to carry and use, Stabilization time does not exceed 5 seconds.

$ 152.00

With 0.01g High Accuracy and +/- 0.03g Nonlinear Error, Support Automatic calibration, counting function and unit conversion, with RS232 Interface and Φ 125mm pan, Stabilization time does not exceed 5 seconds.

$ 196.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Sand Abrasion Tester for detecting the wear resistance of thermal spray coatings
This article introduces the method of using a sand falling tester to evaluate the wear resistance of thermal spray coatings. Thermal spray coatings are widely used in fields such as machinery and aviation, with wear resistance being a critical performance indicator.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
Solvent Rub Tester for Measuring the Solvent Resistance of Cured Coatings
This article introduces the method of testing the solvent resistance of cured colored paints using a solvent-resistant wiping instrument. The test evaluates coating performance by simulating solvent erosion and mechanical wiping, based on the number of wipes or surface changes.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.