Velocity range 0.01-10 m/s, flow measurement error ≤ 1.5%, using measuring Rod positioning measurement method, lightweight structure and support automatic calculation of flow rate formula.
Measurement accuracy better than +/- 2% with high definition color screen progress bar, data locking and real-time dynamic Adjustment.
Simultaneous measurement of infrared, ultraviolet blocking rate and visible light transmittance, resolution up to 0.1%, accuracy better than +/- 2%. Using high definition color screen progress bar visual display, with data locking and real-time dynamic Adjustment to ensure accurate measurement.
It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.
The equipment can test three outsoles at the same time, the folding angle is 90 ° +/- 2 °, the folding speed is adjustable from 5 to 150rpm, and the tortuous performance of the sole is evaluated by measuring the growth rate of the incision.
Simultaneous measurement of UV radiation intensity and barrier rate, Light spectrum Response 260-380nm, power range 0-40000uW/cm ², automatic conversion barrier rate and direct display, Portable design is easy to use.
Range 20~ 600000mPa · s, repRoducibility +/- 0.5% F. S, LCD screen can display viscosity, shear rate, Rotation speed and other Multi-ParaMeters, support stepless speed control and data printing output.
Rotation speed is accurate and stable with high subdivision drive stepper motor, built-in RTD temperature sensor real-time monitoring sample temperature accuracy 0.1 ℃, support 2000 kinds of shear rate stepless setting and synchronous display Multi-ParaMeter.
The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.
The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.
Shear rate 3.84N, sample volume 0.5ml, suitable for NTV-CAP1 host, suitable for a variety of viscosity range measurement.
Velocity range 0.01-5 m/s, error ≤ 1.5%, using measuring Rod positioning and automatic calculation, simple and lightweight structure, support -10 ℃ -50 ℃ Operating temperature, stable and reliable.
Featuring a Cotex-M4 ARM processor, it employs pneumatic sample clamping and an integrated weighing mechanism to achieve fully automated measurement. The oscillation frequency is adjustable from 50 to 200 times per minute, with a weighing resolution of up to 0.001g.
Adopting multi-channel mechanical compression refrigeration system and frequency conversion technology, the energy consumption is reduced by 20%; with a linear temperature rise and fall rate of 15 ° C/min, the temperature uniformity is less than or equal to 2 ° C through the forced air duct system; 120 sets of program editing and remote visual control are supported.
The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.