Measurement accuracy, aging resistance and long life, temperature measurement range -10 ℃~ 40 ℃, humidity measurement range 0% RH~ 90% RH.
Microcomputer and anti-interference technology implementation of rapid precision measurement, temperature range -10~ 60 ℃ error +/- 0.5 ℃, humidity range 10~ 95% RH error 2.5% +/- 1%, automatic memory MAX Maximum MIN Minimum and final measurement value.
Measurement dew point range -40~ 40 ℃, Humidity 10~ 95% RH, automatic recording MAX Maximum, MIN Minimum and last value, Sampling time 0.4 seconds, easy to carry and strong structure.
Using memory metal alloy material, temperature measurement range -20~ 50 ℃, humidity measurement range 0~ 99% RH, aging resistance and accurate Measurement, suitable for a variety of environment monitoring needs.
Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.
Measurement accuracy is ensured by memory metal alloy material, temperature range -10~ 40 ℃ error +/- 1.5 ℃, humidity range 10~ 90% RH error +/- 5%, aging resistant design to extend service life.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.
Temperature range -60~ 150 ℃, humidity control range 20~ 98% R.H., with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring, to meet the needs of complex environment testing.
Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring, suitable for complex environment simulation test.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Temperature range -50~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and automatic calculation function, support reservation start and network monitoring to ensure test accuracy and convenient operation.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.