Micro Analytical Balance

Micro electronic balances operate based on the principle of electromagnetic force balance, precisely measuring minute masses through changes in electric current. They are used in laboratories for weighing trace samples, checking raw material ratios in the coatings and ink industry, and analyzing additive content in the plastics industry.
Selection
When selecting, focus on ensuring the measurement range meets the sample weight, the reading accuracy aligns with testing requirements, consider the impact of environmental temperature fluctuations, check the completeness of calibration functions, verify the effectiveness of the windbreak structure, and evaluate the compatibility of data interfaces with the existing system.

Terms

Standards

Instruments

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow star pan design, effectively reduce airflow and static interference, improve weighing accuracy and Stability.

$ 2171.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow pan design, effectively reduce airflow and static interference, improve weighing Stability.

$ 1848.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

Using electromagnetic force equilibrating Sensor, automatic timing internal calibrating to ensure accuracy, equipped with negative LCD screen, anti-static Glass and hollow star pan to improve weighing accuracy and Stability, support a variety of communication and printing functions.

$ 2494.00

Using electromagnetic force equilibrating Sensor, the highest accuracy of 0.01mg, dual range weighing range 210g/82g, built-in Automatic calibration and micro sample optimization function, Response fast and stable.

$ 2663.00

Using electromagnetic force equilibrating Sensor technology, the highest accuracy of 0.01mg, with dual range function, optimization of micro sample response, built-in Automatic calibration and a variety of weighing modes, transparent windshield design.

$ 2058.00

Dual range design maximum accuracy 0.01mg, using electromagnetic force equilibrating Sensor and micro sample optimization function, fast response speed, fault detection and overload protection to ensure stability and reliability.

$ 2886.00

With automatic dual range double accuracy function, accuracy 0.2mg, seven shock filter adjustable, support a variety of weighing modes such as density direct reading and dynamic weighing, to ensure fast and stable measurement.

$ 448.00

With 0.001g-0.1g accuracy and automatic dual range function, the metal shell is sturdy and durable, and the six-stage shock-proof filter is adjustable. It supports a variety of weighing modes such as density direct reading and dynamic weighing to ensure fast and stable measurement.

$ 357.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy data connection.

$ 425.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.