Air dew point Meter

The air dew point meter detects the condensation temperature of water vapor by cooling a mirror surface, reflecting the air humidity. It is used to monitor the moisture content in dry environments and compressed air systems, preventing equipment condensation or product moisture.
Selection
Select a model with a measurement range of -80℃ to 20℃, ensuring accuracy within ±2℃; choose a shockproof probe for industrial environments and a portable one for laboratory use; calibrate every six months and ensure compatibility with gas media such as nitrogen.

Terms

Standards

Instruments

Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.

$ 677.00

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.

$ 830.00

Microprocessor control to ensure stability, measurement speed of 0.4 seconds, dew point range -20~ 40 ℃, small size and easy to carry, support automatic shutdown and backlight display.

$ 306.00

Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.

$ 1114.00

Measurement dew point range -40~ 40 ℃, Humidity 10~ 95% RH, automatic recording MAX Maximum, MIN Minimum and last value, Sampling time 0.4 seconds, easy to carry and strong structure.

$ 275.00

Measurement principle of cold mirror to eliminate system inertia error, accuracy of +/- 0.2 ° C, built-in electronic flowMeter to monitor 15-60L/h gas flow, system stability without repeability calibration.

$ 14371.00

Measurement accuracy up to +/- 0.2 ° C, built-in electronic flowMeter to monitor gas flow in real time to ensure stable and reliable measurement performance.

$ 2463.00

Quickly calculate the dew point through the wet-bulb temperature Measurement principle, support direct reading of relative humidity, integrated temperature unit conversion function, easy operation without complicated settings.

$ 240.00

Built-in High Sensitivity Sensor ensures +/- 3% Humidity accuracy and +/- 0.5 ° C temperature accuracy, with 2500 data storage and USB transmission functions, robust protection design adapts to indoor and outdoor environments.

$ 1043.00

High Accuracy Sensor, Measurement range -40~ 40 ℃, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, strong anti-interference for quick on-site detection.

$ 306.00

Probe split structure can measure a variety of temperature paraMeters, with 2500 data storage capacity, high contrast ratio display and USB interface for easy data management, in line with many international standards to ensure measurement accuracy.

$ 1196.00

Simultaneous measurement environment Humidity and surface temperature, accuracy of +/- 0.5 ℃, storage of 20000 readings, support for a variety of K-type Probe extended measurement, with real-time graphics display and wireless transmission function.

$ 1716.00

High Accuracy Sensor for Multi-ParaMeter simultaneous measurement, Measurement speed up to 0.4 seconds, temperature error +/- 0.5 ℃, with backlight display and automatic shutdown function, portable design for on-site rapid detection.

$ 252.00

Built-in Probe can store 20,000 measurement readings, with 0.1 ℃ resolution, support real-time graphical display and custom paraMeter alarm, data transmission and device connection via WiFi and Bluetooth.

$ 1561.00

Articles

Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
What is the difference between the Bendtsen method and the Gurley method for measuring paper air permeability using an air permeability tester?
The air permeability of paper is a key indicator for evaluating its structural compactness and suitability, especially crucial in fields such as packaging, filtration, and specialty papers. The Bendtsen and Gurley methods are two classic and widely used techniques for determining paper permeability.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.