Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.
Using rectangular platinum ElectRode, the ElectRode force is 1.0N +/- 0.05N, the test voltage is adjustable from 100 to 600V, and the voltage drop does not exceed 10% when the short-circuit current is 1.0 +/- 0.1A. The dripping device can accurately control the dripping volume and time interval.
Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using rectangular platinum plating ElectRode, drop time interval of 30 +/- 1 seconds, with automatic cut-off protection function.
Sterling silver cathode and zinc anode construction, integrated temperature sensor for instant measurement without conditioning time, thin permeable membrane isolates Sensor and allows oxygen to pass, generating current to determine oxygen concentration.
Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.
Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.
Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.
Support 0 °, 10 °, 30 ° multi-angle test, equipped with 250mL liquid discharge funnel and 500mL measuringflask, can meet the needs of sanitary napkins and diapers at the same time, such as slippery penetration, re-penetration and other penetration performance measurement.
Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, error +/- 3%, support single and continuous Measurement mode, automatic identification of matrix material and memory calibrated value, easy to operate.
Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.
Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.
Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.
Touchscreen control, automatic constant pressure gas to ensure that the experiment in the preset vacuum, Vacuum Level range of 0~ -90KPa, a key operation automatically end the test, stable and durable performance.
Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.
Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.