Multi-functional Puller

The multifunctional pull-off tester applies vertical tensile force through mechanical or hydraulic devices to detect the adhesion between coatings, adhesive layers, and substrates. It is used to evaluate the bonding strength of coatings and adhesives on surfaces such as metal and concrete, thereby assessing construction quality and material compatibility.
Selection
When selecting, consider matching the maximum tensile range to the strength of the test material, ensuring the fixture is compatible with the sample's shape and size, and verifying that the accuracy meets industry standards. Choose between manual or electric operation based on on-site requirements, and check the equipment's calibration certificate and protective functions.

Terms

Standards

Instruments

16Mm large diaMeter is suitable for striped fabric and leather measurement, Repeatability Delta E * ab < 0.05, with multi-functional test components can measure liquid, powder and other samples to improve measurement accuracy.

$ 1897.00

Temperature range RT + 5~ 60 ℃, Oscillation Frequency 0~ 320rpm, support rotary and reciprocating oscillation mode, liner made of stainless steel corrosion resistance, stepless speed control smooth operation.

$ 883.00

Maximum pull-out force 40kN, using three-point reaction support and post-loading pull-out method principle, with color Touchscreen display force value and time Linear dispersion, support automatic storage of 10000 data.

$ 837.00

With 0~ 300rpm stepless speed regulation and 20mm swing amplitude, the multi-functional spring bottle test rack supports a variety of comparison experiments, and the low center of gravity of the whole machine ensures stable and reliable continuous work.

$ 298.00

Equipped with multi-functional test components to measure liquid and powder samples, 8mm measurement caliber to ensure accurate positioning, Repeatability fluctuation is less than 0.07 on average, light positioning function simplifies the operation process.

$ 1655.00

With a multi-functional spring bottle test rack, it supports a variety of comparative experiments; the stepless speed range is 0~ 250rpm, and the pendulum amplitude is 25mm; the center of gravity of the whole machine is low, and the continuous work is stable and reliable.

$ 364.00

Temperature control accuracy of +/- 1 ℃, Oscillation Frequency start~ 300rpm, with oxygen holes to ensure full oxygen, equipped with multi-functional spring bottle rack for a variety of comparative experiments, stepless speed control smooth operation and safety.

$ 503.00

The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.

$ 1977.00

Temperature control accuracy, 0~ 320rpm stepless speed, stainless steel cavity corrosion resistance, multi-functional spring bottle rack for a variety of comparative tests.

$ 704.00

304 stainless steel material to prevent rusting, Tapped Density vibration amplitude 1-15mm adjustable, equipped with Hall Flow velocity Meter function, support 3 different volume measuringflask test, to meet a variety of international standards.

$ 5528.00

The frequency conversion motor is used to achieve stepless speed regulation of 60~ 8000rpm, and the digital PID control accuracy is high. It is equipped with dispersed impellers and sand grinding blades to adapt to different experimental needs, and the relationship between material viscosity and reaction rate can be directly calculated.

$ 711.00

Temperature control accuracy of +/- 0.1 ℃, Oscillation Frequency 0-320rpm, using multi-functional spring bottle test rack, suitable for a variety of comparative tests, smooth operation and easy operation.

$ 1042.00

Maximum load 5KN, suitable for a variety of material testing, multi-functional design can be adapted to different samples, stable and reliable clamping, to meet the laboratory's diverse mechanical properties testing needs.

$ 332.00

Microcomputer Controlled Temperature Frequency Time, Large Screen LCD Display Three ParaMeters, Low Heat Dispersion Brushless DC Motor Provide 40~ 300rpm Wide Speed Regulation, With Automatic Stop and Load Regulation Functions.

$ 638.00

Temperature control accuracy of +/- 0.1 ℃, Oscillation Frequency 0-320rpm, support for swirling and reciprocating oscillation, multi-functional spring bottle rack for comparison test, easy to operate, safe and smooth operation.

$ 1284.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.