With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.
Measurement range 0.000~ 1.000mg/L, including 100mL molybdate solution, 25 packs of ascorbic acid powder and 25 packs of potassium persulfate powder, suitable for water quality total phosphorus detection.
Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.
Colorimetric digestion integrated tube operation, no need to transfer liquid; Measurement range 0~ 20mg/L, detection of the lower limit of 0.01mg/L; multiple measurements of water samples and remove abnormal values, improve accuracy; with abnormal detection prompt function.
Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.
Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.
Colorimetric integrated tube design, supports more than 10 measurements to take the average value, measurement error ≤ +/- 5%, built-in 30,000 data storage and thermal printer, can expand the detection of ammonia nitrogen, total nitrogen and other paraMeters.
Adopt digestion Colorimetric integrated tube design, no liquid transfer; support more than 10 measurements to take the average value, error ≤ +/- 5%; can store 30,000 data, compatible with 16mm and 25mm Colorimetric tubes.
Measurement range 0~ 1.5mg/L, resolution 0.01mg/L, eliminating human error and improving measurement accuracy.
Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.
Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.
Adopt sealing high temperature digestion technology, measurement range 0.02~ 10mg/L, Indication Error ≤ +/- 5% FS, equipped with imported high luminance Illuminant and narrow band filter system, support 16 water sample batch processing, Optical inspection stability and good corrosion resistance.
Colorimetric integrated tube design, no need to transfer liquid, can be more than 10 times of measurement and remove the abnormal value to take the average, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in 30,000 data storage and thermal printer.
15 minutes to quickly heat up to the set temperature, temperature control accuracy of +/- 0.5 ℃, using multi-point calibrated to eliminate temperature errors, standard imported Glass digestion tube resistant to sudden cooling and sudden heating without bursting.
36-Hole design supports batch processing, temperature control accuracy of +/- 0.5 ℃, rapid heating to set temperature in 15 minutes, multi-point calibrating to eliminate measurement errors, standard imported glass tube anti-burst.