Vacuum Drying Incubator

The vacuum drying incubator reduces the internal air pressure by evacuating air, allowing moisture to evaporate rapidly at low temperatures while maintaining a set temperature environment. It is used for experimental processes requiring low-oxygen or anhydrous conditions, such as sample drying, material curing, and microbial cultivation.
Selection
Determine the temperature range and vacuum requirements based on the sample characteristics; consider the compatibility between the chamber volume and the sample quantity; pay attention to heating uniformity and vacuum pump performance; check material corrosion resistance and sealing; verify that temperature control accuracy and safety configurations meet experimental needs.

Terms

Standards

Instruments

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

Vacuum heating drying technology, Vacuum Level up to -0.098MPa, pumping 80-120 liters/min, drying time is only 4-6 minutes, with intelligent PID temperature control and over-temperature alarm function, easy and safe operation.

$ 2623.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

Double station design can process two samples at the same time, Vacuum Level up to -0.098MPa, drying time only 4-6 minutes, suitable for rapid drying of wet paper samples with a diaMeter of no more than 200mm.

$ 4914.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

The digital vacuum Gauge is used to automatically control the Vacuum Level, with an accuracy of +/- 1%; the heating element is located in the Shelf of the box to shorten the heating time by 50%; the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, effectively improving the drying efficiency.

$ 1655.00

The vacuum environment effectively reduces the boiling point of the liquid and prevents the analysis of heat-sensitive substances; the Vacuum Level < 133Pa ensures efficient drying; the microcomputer PID control realizes accurate temperature control; the multi-layer independent heating system makes the temperature distribution more uniform.

$ 896.00

The vacuum pressure plate is made of pure bronze, the drying temperature can be adjusted from room temperature to 120 ℃, equipped with double drying stations and intelligent drainage system, and the paper uniformity can reach 96.

$ 12596.00

Using vacuum environment to reduce the boiling point of liquid, drying temperature RT + 10~ 250 ℃, vacuum degree of 133Pa, can effectively shorten the powder sample drying time and prevent oxidation, double-decked Glass door is easy to observe.

$ 753.00

Cuboid studios improve space utilization, drying time is shortened by more than 40% compared with traditional equipment; double-decked tempered Glass doors are easy to observe, and mechanical Dial vacuum Meters can achieve 133Pa Vacuum Level.

$ 720.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

Vacuum environment can reduce the boiling point of liquid, suitable for drying heat sensitive substances, Vacuum Level < 133Pa, temperature control accuracy +/- 0.5 ℃, effectively shorten the drying time and prevent sample oxidation or explosion.

$ 1208.00

The cuboid studio improves the volume utilization rate, the Vacuum Level control range is 10~ 105Pa accuracy +/- 1%, the programmed vacuum cycle accelerates the drying, and the 7 groups of 63-step programmable temperature control realize the whole process control.

$ 2762.00

Cuboid Studio improves space utilization and shortens drying time by more than 40%; Double-decked Tempered Glass Door for easy observation, adjustable box door to ensure high Vacuum Level; Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa.

$ 837.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Zero-span tensile strength tester measures the tensile strength of wet pulp.
This article introduces the method of measuring the tensile strength of wet pulp using a zero-span tensile strength tester. Traditional testing is often conducted after the pulp is dried, but testing in the wet state can more directly reflect the bonding potential between fibers.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
Preparation of Paint Film Test Panels
The standardized preparation of paint film test panels is fundamental for accurately assessing the performance of paint films. The entire process includes key steps such as substrate selection and pretreatment, paint preparation, coating, drying and curing, thickness measurement, and curing.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.