UV Moisture Meter

The ultraviolet moisture analyzer utilizes the characteristic that water molecules absorb light intensity at specific ultraviolet bands to calculate moisture content by measuring the sample's absorption of ultraviolet light. It is used for rapid moisture detection in materials such as coatings and plastics, making it suitable for quality control on production sites.
Selection
When selecting, consider matching the sample form to the instrument structure, ensuring the moisture range covers the detection needs, the accuracy meets process standards, the operation interface suits the usage environment, and the maintenance costs align with the frequency of use.

Terms

Standards

Instruments

Effective application width up to 500mm, UV curing length 1000mm, using Touchscreen control, support 0-5m/min pRoduction speed, with tension control unwinding and adjustable UV UV light intensity 1-30mw/cm ² to ensure uniform curing.

$ 24279.00

Simultaneous measurement of UV energy, intensity and temperature, support four-band UV Power measurement, Data storage up to 60,000 Power data, high temperature design can run for a long time in 100 ℃ environment, sampling speed up to 2048 times/second.

$ 990.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

PRoduction speed 0-5m/min, effective application width ≤ 300mm, using scraping with UV light curing, drying tunnel length of 1 Meter, with tension control unwinding and Touchscreen operation.

$ 16210.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

With heating and UV curing functions, Spreader thickness is adjustable from 0 to 10mm, speed is 5 to 200mm/s, support Touchscreen control and a variety of customization options.

$ 8465.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Application width up to 400mm, pRoduction speed 0-5m/min adjustable, UV light curing area 400 * 1000mm, main peak wavelength 365nm, equipped with tension control unwinding and Touchscreen Operating interface to achieve stable Spreader and rapid curing.

$ 14597.00

Adopt scraping method, equipped with 1 Meter Oven and UV light curing system, curing area 600 * 500mm, main peak wavelength 365nm, pRoduction speed 0-5m/min, with tension control unwinding to ensure uniform and stable Spreader.

$ 21051.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Adopt bar coating method, Spreader accuracy +/- 0.001mm, support 1-300mm/s stepless speed regulation. Equipped with Vacuum chuck and heating function, with UV UV curing system, main peak wavelength 365nm, support free adjustment of application length.

$ 4108.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Articles

Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
UV Aging Test Machine Evaluates Outdoor Lifespan of Rubber
This article introduces how ultraviolet aging test chambers assess the service life of rubber in outdoor environments. Rubber exposed outdoors is affected by factors such as sunlight, temperature, and humidity, leading to a gradual decline in its performance.
Selection of UV Energy Meter: Matching Band Response with Energy Range
When selecting a UV energy meter, the key is to match two parameters: spectral response and energy range.
Comparison between Xenon Arc Weathering Chambers and UV Aging Chambers in Weathering Evaluation
Comparison between Xenon Lamp Aging Test Chambers and UV Aging Test Chambers in Weathering Evaluation
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.