Program-controlled high-low temperature thermostatic Bath

The program-controlled high and low temperature thermostatic bath achieves closed-loop control through a heating and cooling system combined with temperature sensors, enabling the liquid inside the bath to automatically undergo temperature changes according to preset programs. It is used in scenarios requiring automatic temperature variations, such as thermal deformation testing of materials and simulating constant-temperature environments for chemical reactions.
Selection
Determine the tank volume based on the size of the test material, select the compressor power according to the experimental temperature range, choose the sensor type based on temperature control accuracy requirements, opt for a stainless steel or titanium alloy tank considering the corrosiveness of the medium, and ensure the number of program steps meets the heating and cooling curve requirements.

Terms

Standards

Instruments

Rotation speed up to 8000rpm, support program-controlled homogeneous gel Linear dispersion storage, miniaturized design saves space, suitable for a variety of substrate coating.

$ 2090.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Spreader accuracy of +/- 0.003mm, thickness range of 0~ 10mm, using Glass coating table and pneumatic feeding system, support infinitely variable speed and remote paraMeter settings to ensure uniform and stable Spreader.

$ 5721.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

Adopt proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30 program settings, equipped with maintenance-free pressure pump and multiple Safety protection system, working noise is less than 45 decibels.

$ 2163.00

The temperature fluctuation is controlled within +/- 0.05 ℃, the non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and multiple Safety protection devices are equipped to ensure stable and reliable operation.

$ 1237.00

Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.

$ 1647.00

Using non-fluorine environmental protection Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor and centrifugal circulation pump, to avoid its own heat affecting the temperature field, support multi-stage program temperature control.

$ 1300.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet diverse experimental needs.

$ 942.00

Equipped with high and low temperature thermostatic cell, Temperature range 0-110 ℃, PT100 Probe real-time monitoring, liquid temperature can be corrected to ensure the accuracy of test data.

$ 353.00

Double Compressor refrigeration system is adopted to ensure rapid cooling, Tank volume 6L, Pump Flow rate 8L/min to ensure liquid uniformity, Temperature Fluctuation is controlled within +/- 0.05 ℃, and the overall foaming process reduces cooling loss.

$ 946.00

Adopt proportional refrigeration and PID control technology, support 30-stage program control, Temperature Fluctuation +/- 0.05K, with multiple safety protections such as water shortage protection and overheating and overflow, and the pump Flow rate reaches 12L/min.

$ 1519.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes turbulence and high uniformity, Temperature Uniformity +/- 0.0050 ℃, with multiple safety functions such as low water level protection and temperature loss protection.

$ 2160.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.