The motion balance calculates the settling velocity of particles by measuring the real-time weight change of an object as it settles in a fluid. It is used to determine the particle size distribution of pigments or fillers in samples such as coatings and inks. During operation, the sample is placed in the fluid, and the variation curve of the balance reading over time during the settling process is recorded.
Selection
When selecting a sedimentation balance, it is important to consider matching the sample characteristics with the sedimentation medium, ensuring the measurement range covers the particle sizes to be tested, verifying that the balance sensitivity meets accuracy requirements, confirming that temperature control functions are suitable for the material properties, ensuring the data acquisition system can fully record the sedimentation process, and making sure the operation interface aligns with user habits.

Terms

Standards

Instruments

Adopt arc reciprocating motion mode, provide four adjustable speeds (21-106rpm) and 2lb/4lb friction load, support 0-999999 automatic shutdown tests, suitable for Abrasion Resistance evaluation.

$ 925.00

Adopting three-dimensional motion mode, Speed range 2450-4450rpm, dual-station operation, noise lower than 65dB, suitable for wet grinding and dry grinding of various sample tissues.

$ 1848.00

The instrument adopts Precision Platinum Resistance Sensor with temperature control accuracy of +/- 0.1 ℃ and kinematic viscosity measurement range of 0~ 10000mm ²/S, which is suitable for viscosity analysis of various liquids under thermostatic conditions.

$ 1330.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy connection to external devices.

$ 656.00

The instrument is equipped with an eight-station synchronous test function, which supports 24mm and 60.5mm Li ShaRu motion trajectories, with a maximum motion range of 60.5mm. It meets a variety of standard requirements, is easy to operate, and counts intuitively.

$ 1660.00

Speed range 2450-4450rpm, double station operation to improve efficiency, noise below 65db to ensure a quiet operating environment.

$ 1848.00

The equipment is equipped with eight independent stations for simultaneous testing, supporting 24mm and 60.5mm Li Sharu motion trajectories, with a maximum motion range of 60.5mm. It uses a 395g fabric weight and a 2385g pressure clock system to achieve multi-standard material wear resistance evaluation.

$ 2981.00

Adopt electric push Rod to drive Spreader movement, adjustable speed range of 2-200mm/s, temperature accuracy +/- 3 ℃, support Vacuum chuck and electric heating function, improve Spreader uniformity and operation convenience.

$ 2494.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, adjustable weighing speed of fast, medium and slow, and equipped with RS-232 interface for data connection.

$ 637.00

Using PID intelligent temperature control technology, Precision temperature control up to +/- 0.1 ℃, equipped with 7-inch Touchscreen and four-hole test position, automatically calculate viscosity and store 50 sets of data, easy and efficient operation.

$ 5399.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for easy data connection.

$ 425.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading within 2 seconds, Measurement speed, Sensitivity adjustable, and equipped with RS-232 interface for data output.

$ 485.00

High Accuracy Electromagnetic Force equilibrating Sensor, stable reading in 2 seconds, Measurement speed, Sensitivity can be adjusted in gears, and equipped with RS-232 interface for data connection.

$ 1151.00

Adopt SMT surface mount technology, with temperature compensation function to make Balance more stable, weighing range 0-6kg, accuracy 1g, support counting and unit conversion function.

$ 181.00

Equipped with six independent stations and two Lisaru motion trajectories, it supports a maximum of 999999 counts, and adopts a movement speed of 50rpm, which can simultaneously test the wear resistance performance of multiple sets of samples.

$ 2258.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.