Vacuum-Sealed Drying Oven

The sealed drying oven generates heat through heating elements, with its sealed structure preventing external air from entering. The internal air circulation system ensures even distribution of heat, facilitating the evaporation of moisture from samples. It is used in laboratories for drying materials such as coatings and plastics, or for storing moisture-sensitive items at specific temperatures.
Selection
When selecting, consider matching the chamber volume to the sample size, ensuring the temperature range covers experimental needs, the temperature control accuracy meets material tolerance, sealing performance is guaranteed through silicone gaskets and latch designs, material corrosion resistance suits the chemical environment, the observation window facilitates process monitoring, and safety devices include over-temperature protection.

Terms

Standards

Instruments

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

The digital vacuum Gauge is used to automatically control the Vacuum Level, with an accuracy of +/- 1%; the heating element is located in the Shelf of the box to shorten the heating time by 50%; the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, effectively improving the drying efficiency.

$ 1655.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Cuboid studios improve space utilization, drying time is shortened by more than 40% compared with traditional equipment; double-decked tempered Glass doors are easy to observe, and mechanical Dial vacuum Meters can achieve 133Pa Vacuum Level.

$ 720.00

The vacuum environment effectively reduces the boiling point of the liquid and prevents the analysis of heat-sensitive substances; the Vacuum Level < 133Pa ensures efficient drying; the microcomputer PID control realizes accurate temperature control; the multi-layer independent heating system makes the temperature distribution more uniform.

$ 896.00

Using vacuum environment to reduce the boiling point of liquid, drying temperature RT + 10~ 250 ℃, vacuum degree of 133Pa, can effectively shorten the powder sample drying time and prevent oxidation, double-decked Glass door is easy to observe.

$ 753.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

Cuboid Studio improves space utilization and shortens drying time by more than 40%; Double-decked Tempered Glass Door for easy observation, adjustable box door to ensure high Vacuum Level; Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa.

$ 837.00

The cuboid studio improves the volume utilization rate, the Vacuum Level control range is 10~ 105Pa accuracy +/- 1%, the programmed vacuum cycle accelerates the drying, and the 7 groups of 63-step programmable temperature control realize the whole process control.

$ 2762.00

The cuboid studio improves the effective volume utilization rate and reduces the drying time by more than 40%; the box door is made of tempered bulletproof double-decked Glass for easy observation, and the studio is made of stainless steel, which is durable and easy to clean; Vacuum Level reaches 133Pa, Temperature range RT + 10~ 200 ℃.

$ 908.00

Vacuum environment can reduce the boiling point of liquid, suitable for drying heat sensitive substances, Vacuum Level < 133Pa, temperature control accuracy +/- 0.5 ℃, effectively shorten the drying time and prevent sample oxidation or explosion.

$ 1208.00

The cuboid studio improves the volume utilization rate, and the drying time is shortened by more than 40% compared with traditional equipment. Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass doors are easy to observe, and silicon door seals ensure high vacuum maintenance.

$ 3699.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Insulation resistance tester measures rubber sealing gaskets.
This article introduces the method of using an insulation resistance tester to inspect rubber sealing gaskets.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
The rain test chamber simulates heavy rain environments to test the waterproof sealing performance of products.
A rain test chamber is a device that simulates rainfall environments, used to evaluate the waterproof performance of product casings or sealed components. It tests electronic products, automotive parts, and other items in accordance with relevant standards by controlling water flow, water pressure, and spray duration.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.