Material Electric Heating Jacket

The electric heating mantle heats via resistance wires, evenly transferring heat to the exterior of the container. It is used in laboratories to heat liquids or samples and is suitable for industries such as chemistry and pharmaceuticals, providing a controllable temperature environment and avoiding the risks associated with direct flame heating.
Selection
When selecting a heating mantle, consider whether the heating temperature range covers your needs, ensure the material is corrosion-resistant, match the size to your container, verify safety features such as overheat protection, and check that the power is compatible with your power supply.

Terms

Standards

Instruments

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Rotation speed 3000rpm, maximum linear speed 33m/s, high dispersion efficiency, strong material shear force, the formation of uniform suspension effect, safe and convenient operation, electric lifting fast fixed sealing barrel.

$ 2676.00

Using high temperature non-alkali fiberglass insulation material sealing resistance wire, large heating area and heating fast, the highest temperature 380 ℃, support internal and external dual Sensor temperature measurement, no open flame design to avoid bumping Glass ware.

$ 170.00

Rotation speed 3000rpm with zirconia bead grinding medium, fineness up to 10um or less; double-decked chilled down jacket design makes the operating temperature rise less than 10º; electric lifting structure is easy to operate and clean, suitable for medium and low viscosity material processing.

$ 2986.00

Adopting high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and no open flame design.

$ 143.00

Adopt high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, support internal and external dual Sensor temperature measurement, large heating area and no open flame design, can work continuously.

$ 160.00

Electric lifting design is light and convenient, the highest Rotation speed of 3000rpm, line speed of 33m/s, double-end sealing structure to ensure the vacuum sealing defoaming effect, suitable for viscosity ≤ 25000cps material.

$ 2779.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the heating is fast, the maximum operating temperature is 380 ℃, and the hemispherical internal thermal design avoids the danger of open flame.

$ 212.00

Rotation speed up to 3000rpm, maximum line speed 33m/s, electric lifting design easy to operate, double-end sealing structure to ensure the vacuum sealing defoaming effect, suitable for viscosity ≤ 25000cps material.

$ 2571.00

The fully enclosed heating plate is designed without open flame, Heating power 3000W, heating up quickly and safely, and the studio stainless steel material has superior corrosion resistance.

$ 236.00

The use of electric lifting system to achieve 320mm Travel adjustment, frequency control range of 60-6900rpm, equipped with multi-specification impeller and chill down jacket structure, can meet the needs of stirring and dispersing under different material viscosity.

$ 1006.00

Mirror stainless steel liner and electric heating film heating, Temperature Uniformity +/- 1 ℃, heating speed, double-decked door design to reduce heat loss, four corners arc easy to clean.

$ 601.00

Electric lifting design is light and convenient, the highest Rotation speed 3000rpm, linear speed of 33m/s, double-end sealing structure to ensure vacuum sealing defoaming, suitable for viscosity ≤ 25000cps materials.

$ 2883.00

Temperature range environment temperature to 380 ℃, can work continuously, heating element surface temperature up to 380 ℃, insulation layer sealing resistance wire design is safe and reliable.

$ 110.00

Articles

Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Melt flow index instrument controls the flowability and stability of polypropylene injection molding process.
This article explores how to assess and regulate the stability of polypropylene's flowability in injection molding processes by measuring its melt flow rate. It explains the principles behind characterizing flowability and analyzes the impact of factors such as material batch variations and process parameters on stability.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials