Portable thermal infrared imager

Portable thermal infrared imagers generate thermal distribution images by detecting infrared radiation from object surfaces, used for quickly identifying temperature anomalies. In industrial settings, they are employed for on-site diagnostics such as detecting equipment overheating, pipeline blockages, and material defects.
Selection
When selecting, consider that the detection temperature range should cover the required targets, the spatial resolution should meet the minimum detection size, and the thermal sensitivity should be suitable for temperature difference recognition. Pay attention to environmental adaptability, battery life, and ease of operation, and match the functions according to the actual application scenarios.

Terms

Standards

Instruments

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.

$ 428.00

Measurement accuracy of (3 + L/200) μm, equipped with high resolution CCD and adjustable LED Illuminant to avoid thermal deformation of the workpiece.

$ 12862.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.

$ 444.00

Using Infrared source Nephilometry to reduce Color interference, automatic range conversion ensures accuracy, Measurement range 0.00-250 EBC, accuracy +/- 3% +/- 0.20EBC, built-in GLP function to store calibrated data.

$ 1100.00

Full marble construction ensures Stability, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Illuminant to avoid thermal deformation of workpiece, Support Z-axis image altimetry or contact measurement.

$ 3222.00

LED Infrared source and scattering - transmission light measurement principle, range 0.000-1000NTU, support multi-point calibrating and 2000 data storage, with automatic power-off and USB power supply function, in line with ISO7027 standard.

$ 678.00

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

Full marble construction ensures Stability and rigidity, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Ring Illuminant to avoid thermal deformation of the workpiece, Support manual operation and a variety of accessories options.

$ 2741.00

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

Support ultraviolet-visible infrared three-light transmitance measurement, accuracy of +/- 2%, single continuous Measurement mode, thickness measurement capacity of 10mm, portable design weighing only 120g for easy on-site use.

$ 365.00

Full marble construction ensures Stability, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Illuminant to avoid thermal deformation of workpiece, Support Z-axis image altimetry or probe measurement.

$ 4427.00

All-marble construction ensures Stability, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Illuminant to avoid thermal deformation of workpiece, Support three-axis friction precision transmission and Z-axis image altimetry function.

$ 10693.00

Stability is ensured by all-marble structure, three-axis friction transmission is sensitive without backlash, Measurement accuracy (3 + L/200) μm, adjustable LED Illuminant avoids thermal deformation of workpiece, and supports Z-axis height measurement or probe measurement.

$ 6836.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.