High Temperature Coating Applicator with Scraper

The high-temperature film applicator with a heated platform and adjustable blade evenly spreads coatings on substrates to form uniform wet films, simulating the coating film formation process under high-temperature conditions. It is suitable for laboratory testing of coating heat resistance and leveling properties.
Selection
When selecting, consider the temperature control range and its compatibility with the substrate, the precision of the blade gap affecting coating thickness, the heating platform size matching the sample specifications, the simplicity of the operation interface to ensure ease of use, and the corrosion resistance of the material to extend the equipment's lifespan.

Terms

Standards

Instruments

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Adopt high-quality alloy steel scraper, Hardness and wear resistance and corrosion resistance; Magnetic suction design for quick replacement and cleaning; Film Film thickness 0~ 4500 μ m free adjustment, resolution up to 10 μ m, error only +/- 2 μ m.

$ 291.00

High-quality alloy steel scraper, Hardness and wear resistance and corrosion resistance, Film thickness adjustment range 0-4500 μ m, magnetic suction design for quick replacement and cleaning, differential head accuracy of +/- 2 μ m to ensure uniform and stable film.

$ 251.00

High-quality alloy steel scraper accuracy of +/- 2μm, magnetic suction design for easy cleaning and replacement, Film thickness adjustment range of 0-4500μm to meet the needs of different materials Moulding, acid and alkali corrosion bracket to ensure long-term stable use.

$ 315.00

Adopt removable scraper for easy cleaning and replacement, with bracket design to improve running Stability; Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm adjustable, effective Spreader area of 400 * 300mm, through stepless speed control to ensure uniform Spreader.

$ 2333.00

Spreader width 250mm, wet film thickness adjustment range 0-4500μm, scraper error +/- 2μm, High Accuracy Differential Head Control to meet the needs of various materials Moulding.

$ 340.00

Using removable scraper and vacuum adsorption system, Spreader accuracy +/- 0.003mm, Spreader rate 5~ 180mm/s, heating temperature up to 180 ℃, improve film Stability and uniformity.

$ 7496.00

A wet film with a film thickness of 50~ 675 μ m was prepared by using a coating scraper, and the sag property was observed when placed vertically. The maximum thickness without sag was expressed, which was suitable for Paints testing.

$ 411.00

Equipped with dual coating methods of wire rod and blade, with an infinitely adjustable coating speed of 1–300 mm/s, wire rod accuracy of ±0.001 mm, blade accuracy of ±0.003 mm, and optional heating and vacuum adsorption functions to meet coating requirements of various thicknesses.

$ 9433.00

With bar and Drawdown blade two coating methods, coating speed 1-300mm/s stepless speed regulation, Blade Coating thickness 0.1-10 mm, using clamshell design for easy cleaning, equipped with High Accuracy Film Applicator to ensure Spreader uniformity.

$ 5237.00

The multi-groove coating scraper can scrape 10 wet-films of different thicknesses at one time, the thickness difference of adjacent films is 25um, and the wide film thickness range of 50-675um is supported. It is convenient to visually observe the sag situation by placing the test plate vertically.

$ 315.00

Effective Spreader width 300mm, suitable for all kinds of scraper type Film Applicators, to ensure the uniformity of Spreader, improve the film accuracy and conformity in the experiment or pRoduction.

$ 235.00

Adopting 500 * 700mm Dimensions, used with bar or Film Applicator, is conducive to the smooth and effective film, and improves the convenience of film operation.

$ 227.00

Imported wire Rod to achieve 1 μ m High Accuracy Spreader, scraper Spreader Film thickness range of 0~ 5000 μ m, support 5~ 200mm/s stepless speed control and vacuum adsorption fixation, effectively improve film conformity and operation convenience.

$ 3494.00

Adopt clamshell type Blade Coating head design, easy to clean; coating speed 1~ 300mm/s stepless speed regulation, Spreader accuracy up to +/- 0.003mm, to meet the laboratory High Accuracy film needs.

$ 2978.00

Articles

How should one choose between the blade coating method and the spin coating method for perovskite film deposition experiments?
In the fabrication of perovskite solar cells, spin coating and blade coating are two commonly used film deposition methods, each with its applicable scenarios.
Taber Abrasion Test Method for Wear Resistance of Coating Films
This article introduces the Taber abrasion test method, which is used to evaluate the ability of coatings, such as those on floors, furniture, or car interiors, to resist mechanical wear.
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.