Laboratory humidity and heat chamber

The laboratory humidity and heat chamber simulates high-temperature and high-humidity environments by generating heat through a heater and water vapor through a humidifier. It is used to test the aging resistance, mold resistance, and other properties of materials under humid and hot conditions. It is commonly employed in environmental adaptability testing for products such as electronic components, coatings, and plastics.
Selection
When selecting, pay attention to the temperature range, humidity range, corrosion resistance of the inner chamber material, accuracy of temperature and humidity control, and compatibility between the chamber volume and sample racks. Consider the device's energy consumption and its compatibility with the laboratory's power supply. Check safety protection features such as over-temperature protection, and verify the after-sales response time and availability of commonly used accessories.

Terms

Standards

Instruments

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.

$ 2457.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Adopt TMHM equilibrate Conditioning method, temperature fluctuation +/- 1.0 ℃, humidity deviation +/- 3% RH; with 100 sets of program capacity and P.I.D automatic calculation function, ensure stable and uniform heat preservation Humidity, support multi-stage programmable operation.

$ 2841.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.

$ 5705.00

Adopt equilibrate Conditioning Control system, Temperature Humidity range -60~ 150 ℃, 20~ 98% RH, Equipped with imported Compressor and environmentally friendly refrigerant, High Accuracy and stable operation. Special air circulation design ensures uniformity, built-in multiple protection functions, prolong equipment life.

$ 3640.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Adopt fluorine-free environmental protection design, Humidity Control Range 35-95% RH, input Power 2300W, with PID automatic calculation function, ensure accurate and stable thermal insulation Humidity control, equipped with multiple Safety protection systems.

$ 5405.00

Using French Taikang fully enclosed Compressor, Temperature Fluctuation ≤ +/- 0.5 ℃, Humidity deviation + 2, -3% RH, with 100 sets of program capacity and RS-232/485 communication interface, improve test accuracy and convenience.

$ 10804.00

Articles

Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.
Differences and Selection Between Alternating Damp Heat and Constant Damp Heat Test Methods
Based on the patterns of humidity and temperature changes, they are mainly divided into two categories: constant damp heat tests and cyclic damp heat tests. Both simulate the effects of humid environments on products, but there are significant differences in their stress application methods, failure mechanisms, and applicable standards.