High-speed disperser for paint

The Paint Quick Mixer uses high-speed rotating serrated blades to generate shear forces, rapidly mixing paint powder with liquid. It is used for the pre-dispersion process of laboratory paints and inks, effectively reducing material mixing time.
Selection
When selecting, consider matching the sample viscosity with the motor power, using stainless steel material to accommodate corrosive raw materials, and ensuring the speed adjustment range covers 200-3000 rpm. Pay attention to the compatibility of fixtures with different container sizes and the mechanical seal structure for easy cleaning and maintenance.

Terms

Standards

Instruments

Speed range 0~ 20000rpm wide adjustable, equipped with high-speed series motor and stable silicon control system, integrated photoelectric speed measurement to ensure accurate reading, compact structure and convenient operation.

$ 351.00

Adopt thyristor high-speed adjustment system, photoelectric speed measurement electronic circuit to ensure reliable Rotation speed, homogenization knife Speed range of 22000rpm, Processing capacity 1000ml, easy to operate and intuitive reading.

$ 361.00

The equipment uses a spring lift system, lift Travel 200mm, speed range of 60~ 8000rpm, can adapt to different experimental needs, through the digital PID technology implementation High Accuracy control, and provide dispersed impeller and sand grinding disc.

$ 801.00

The equipment integrates stirring, dispersing, grinding functions, motor Power 750W, speed range 60~ 8000rpm, can handle materials with a viscosity of 100000mPa.s, through high-speed swirl/spin to generate strong shear force to achieve efficient Mixing & dispersing.

$ 675.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, dispersion head generates swirl/spin tangential high line speed under high speed drive, through hydraulic shearing and high frequency mechanical effects to achieve efficient mixing, dispersion and homogenization.

$ 333.00

With a wide speed range of 0~ 10000rpm and 280mm lift Travel, using frequency conversion electromechanical operation quiet noise, support high-speed dispersion, stirring and grinding functions, suitable for 0~ 2L Processing capacity.

$ 772.00

The equipment uses an electronic constant force speed line, digital direct display Rotation speed, speed range of 100 to 8000rpm, maximum processing viscosity of 100000mPa.s, to adapt to different test needs, through high-speed shearing and high-frequency mechanical effects to achieve efficient mixing and dispersion.

$ 436.00

Adopt dual-axis constant force lifting system, lift Travel 200mm, speed range 60-8000rpm, digital direct display Rotation speed, equipped with dispersed impeller and sand grinding disc, adapt to different experimental needs.

$ 653.00

Using 750W Motor Power, the speed range is 60-8000rpm, which integrates the three functions of stirring and dispersing grinding, and generates a strong shear force through high-speed swirling/spinning to achieve efficient Mixing & dispersing effect.

$ 756.00

Using frequency conversion control to achieve a wide range of 60~ 8000rpm speed regulation, the maximum processing viscosity of 100000mPa.s, set dispersed ground stirring function in one, through high-speed swirl/spin to pRoduce a strong shear effect to improve the mixing efficiency.

$ 515.00

Set dispersion and Stir functions in one, the two processes of dispersion and homogenization are completed by one machine, with high efficiency, good mixing effect and easy cleaning. Speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, electric lifting mode is simple and convenient to operate.

$ 493.00

Set stirring, dispersing, grinding three functions in one, motor Power 750W, processing viscosity of 100000mPa.s, using frequency control to achieve 60-8000rpm stepless speed regulation, through high-speed swirl/spin to pRoduce strong shear effect to achieve efficient mixing.

$ 687.00

Adopt frequency conversion motor to achieve stepless speed regulation of 60-8000rpm, equipped with dispersed impeller and sand grinding blades, dual-axis constant force lifting system is easy to operate, and digital PID technology ensures Rotation speed control accuracy.

$ 493.00

Speed range 60~ 8000rpm, Power 550W, using variable frequency motor to achieve stepless speed regulation, digital direct display Rotation speed, dual-axis constant force lifting system is easy to operate, low noise and no interference.

$ 504.00

Adopt spring electric lifting system, Travel 200mm; Frequency conversion motor Power 750W, speed range 60-8000rpm; with dispersed impeller and sand grinding blades, can be adapted to jacket chill down Mixing Tank for multi-purpose experimental operation.

$ 733.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.