Paper Moisture Meter

The paper moisture meter measures the dielectric constant or resistance value of paper to reflect its moisture content, utilizing the influence of moisture on electrical parameters for detection. This instrument is used in paper production and storage processes to monitor paper humidity, preventing issues such as deformation and paper jams caused by improper moisture levels.
Selection
When selecting a paper moisture meter, it is essential to consider a measurement range that covers common paper moisture content, a probe type suitable for flat or roll materials, a user-friendly operation interface, stable calibration functions, and a balance between portability and fixed installation requirements, while also referring to practical industry application cases.

Terms

Standards

Instruments

Can store 240 sets of data, Measurement range 0-100%, provide a variety of measurement code selection, support LED status indication and LCD digital display, easy to accurately determine the moisture status.

$ 241.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using conductivity Measurement principle, can measure 0~ 80% moisture range, accuracy +/- (0.5% n + 1), with 240 data storage and USB/RS-232/Bluetooth communication function.

$ 235.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Conductivity Detector principle, Measurement range 2-95%, accuracy 0.1%, Response Time only 1 second, Humidity compensation technology to ensure measurement Stability, support MAX Maximum hold and automatic shutdown function.

$ 159.00

Measurement range 0~ 80%, resolution 0.1, digital and LED dual Display mode, support USB, RS-232 and Bluetooth data output.

$ 194.00

Using resistance principle and temperature and humidity compensation technology, the measurement range is 0-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, and the portable design weight is about 203 grams, which is suitable for on-site rapid detection.

$ 144.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.

$ 359.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

Measurement principle of resistance method, accuracy of +/- 1%, equipped with 610mm detachable long probe, can measure different depths of grain moisture, support voice broadcast and a variety of function settings, suitable for a variety of grain moisture detection.

$ 97.00

Articles

Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
IGT Printability Tester Evaluates Paper Surface Pick Resistance
This article introduces how to use the IGT printability tester to evaluate the surface pick resistance of paper. Picking refers to the phenomenon where the tack force of the ink is too high during printing, causing the surface fibers of the paper to be lifted, which affects print quality.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Contact angle measuring instrument measures the surface wettability of paper.
The contact angle goniometer evaluates wettability by measuring the contact angle of a liquid droplet on the surface of paper, based on the principle of Young's equation. The static drop method is commonly used for measurement, requiring control over sample flatness, environmental conditions, and droplet volume, while also considering the influence of surface roughness.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Standard Method for Determining the Beating Degree of Pulp Using a PFI Mill
This article introduces the standard method for measuring the degree of pulp beating using a PFI mill. The beating degree is a key indicator of the extent of pulp fiber processing and directly affects paper quality.