Colorimetric digestion integrated tube operation, no need to transfer liquid, Measurement range 0~ 250mg/L, detection limit of 0.5mg/L, multiple measurements of water samples to take the average value to reduce errors, suggesting detection of abnormalities.
Colorimetric integrated tube design is adopted, with a detection limit of 0.5mg/L, high temperature digestion at 125 ° C, built-in 4000 data storage and a variety of transmission interfaces to meet the needs of on-site rapid detection.
Colorimetric integrated tube with digestion is used to realize detection integration, the detection limit is 0.01mg/L, Optical inspection Stability ≤ +/- 0.001A/20min, supports multiple power supply modes and wireless data transmission, and the portable design is suitable for on-site rapid detection.
Adopt digestion Colorimetric integrated tube design, detection limit of 0.02mg/L, support 125 ℃ closed digestion, built-in imported cold light source life of 100,000 hours, can store 4000 sets of data and support multi-mode power supply.
Colorimetric digestion integrated tube operation, no need to transfer liquid; Measurement range 0~ 20mg/L, detection of the lower limit of 0.01mg/L; multiple measurements of water samples and remove abnormal values, improve accuracy; with abnormal detection prompt function.
The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, digests Colorimetric integrated tube to make the measurement safe and fast, can store 4000 sets of data and support multi-mode power supply.
Adopt digestion Colorimetric integrated tube design for safer and more convenient detection; minimum display value of 0.001mg/L, high Sensitivity; built-in rechargeable lithium battery, support long standby, power only 0.3W, strong portability.
The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, is equipped with a digestion Colorimetric integrated tube to achieve safe and fast measurement, and has 4000 sets of data storage and a variety of transmission interfaces.
Measurement range 0~ 1500mg/L, 10mL Colorimetric tube Encasement, 25 boxes convenient for batch use, suitable for water quality chemical oxygen demand detection and analysis.
Measurement range 0~ 150mg/L, 10mL Colorimetric Encasement, 25/box, suitable for rapid detection of chemical oxygen demand in water quality.
Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.
Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.
Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.
Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.
Using digestion Colorimetric integrated tube technology, the detection limit reaches 0.01mg/L, supports 16 water sample batches, and has 30,000 data storage and abnormal prompt functions to ensure accurate and stable detection.