Fully Automatic ElectRode Coater

The fully automatic electrode Coater uniformly applies slurry onto the substrate surface through a mechanical transmission system and controls the coating thickness using a doctor blade. It is used for laboratory electrode sample preparation, ensuring coating consistency and repeatability, and is suitable for fields such as battery materials and conductive thin films.
Selection
When selecting, consider the match between the coating width and substrate size, ensure the coating thickness range covers experimental needs, and pay attention to the adaptability of slurry viscosity. The equipment should provide stable speed control and uniform coating results, with a simple operation interface and easy maintenance.

Terms

Instruments

Equipped with planar pH ElectRode, Measurement accuracy is 0.05pH, support 2 point calibrating and automatic temperature compensation, fully waterproof design and replaceable ElectRode, prolong service life.

$ 141.00

Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.

$ 1332.00

The fully automatic electronically controlled hydraulic pump provides smooth and continuous pulling force with +/- 1% accuracy, built-in rechargeable battery supports 200 tests, and IP65 Protection Rating ensures durability.

$ 4212.00

Platinum ElectRode ensures fast and stable measurement, supports 1-3 point calibrating and automatic temperature compensation, salinity Measurement range 0-80ppt, conductivity covers 100μS/cm to 200mS/cm, with automatic end lock and fully waterproof design.

$ 167.00

Measurement accuracy of 0.01 pH, support for automatic temperature compensation and 1 to 3 point calibrating, fully waterproof design for harsh environments, can replace ElectRode to reduce maintenance costs.

$ 164.00

Fast Response with Planar pH ElectRode, Automatic temperature compensation and 1-3 point Adjustment, Measurement accuracy of 0.01 pH, Support automatic end point locking and full waterproof design.

$ 173.00

The Spin Coater is controlled by touch screen, the acceleration range is 100~ 4000rpm/s, and the speed can be automatically corrected by A/K selection. The motor torque is large and the operation is smooth, which is suitable for the assembly line process.

$ 2494.00

Glass sensitive film can fully sense the pH value of liquid or semi-solid substances, gel KCL reference solution to ensure long-term use of ElectRode, built-in temperature resistance real-time sensing sample temperature, Measurement range 0~ 14pH.

$ 109.00

With 2 point button calibrating and automatic temperature compensation, Measurement accuracy of 0.05pH, with replaceable ElectRode design, full waterproof performance to ensure stable use in harsh environments.

$ 164.00

Measurement range of dissolved oxygen 0.00-45 mg/L, accuracy +/- 1.5%, support automatic temperature compensation and salinity compensation, equipped with polarographic ElectRode, can store 1000 sets of data, suitable for a variety of environment detection.

$ 1316.00

Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.

$ 4914.00

Designed for Calcium Composite ElectRode, 250ml Standard Encasement is provided to ensure ElectRode calibrating accuracy and long-term Stability for a variety of analytical scenarios.

$ 110.00

A calibrated solution specially designed for Iodine Ion Composite ElectRode, 250ml standard Encasement, provides a stable and reliable calibrated benchmark to ensure ElectRode Measurement accuracy and Repeatability.

$ 110.00

A calibrated solution specially designed for bromine ion composite ElectRode, with a capacity of 250ml, to ensure measurement accuracy and ElectRode performance stability, suitable for a variety of detection scenarios.

$ 110.00

ElectRode planar design, direct measurement of semi-solid substances, Measurement accuracy of 0.05pH, support automatic temperature compensation and 2 point calibrating, waterproof structure to ensure harsh environment use.

$ 159.00

Articles

Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Actual Coating Thickness Deviation of Stainless Steel Wire Rod Coaters at Different Slurry Solid Contents
This article analyzes the actual coating thickness deviation of stainless steel wire rod coaters under different slurry solid contents. The study finds that the solid content of the slurry affects its viscosity and flowability, leading to deviations in the actual coating thickness from the theoretical value.
Coating film preparation techniques: comparison between wire-wound applicators and wet film preparators
This article compares two commonly used tools in laboratory coating film preparation: the wire rod coater and the wet film applicator.
Application of Wire Bar Coater in the Preparation of Coating, Ink, and Printing Samples
A wire-wound rod coater is a laboratory tool used for preparing uniform wet film coatings on flat substrates, widely applied in the production of samples in the coatings, inks, and printing industries.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
The difference between a wire-wound rod coater and an extrusion coating rod
This article primarily compares the technical differences between wire-wound and extrusion coating rods. Although they are interchangeable in most scenarios, there are subtle variations in liquid loading capacity due to their distinct groove principles.
Wire rod Applicator: Principles, Applications, and Selection Guide - A Precision Coating Tool
This article provides a detailed introduction to the working principles of a Wire rod Applicator, including the mechanism by which it controls wet film thickness through the gap between stainless steel wires. It elaborates on its wide range of applications in fields such as coatings, inks, and lithium batteries, and summarizes its technical advantages, including precise control and ease of operation.