Light Source Light Box

The light source cabinet provides stable lighting conditions through built-in standard light sources and a neutral gray environment. It is used for visual color comparison to detect color consistency of items, and is applied in the textile, printing, and coating industries for color matching and quality control.

Instruments

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.

$ 5366.00

Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.

$ 2623.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illumination up to 3000LX, life more than 10,000 hours, uniform irradiation surface and no stroboscopic, flexible adjustment of light box position and angle according to test requirements.

$ 12305.00

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

The color temperature of the D65 light source is 6500K, the color rendering index is as high as 98, and the all-metal structure is sturdy and durable. The inclined surface of the operating table conforms to visual observation habits, and the light is uniform and stable.

$ 1735.00

The imported cold light source does not need to be preheated for 100,000 hours, the detection limit is 0.01mg/L, and the digestion Colorimetric integrated tube is safe and fast. It can store 4000 sets of data and has a variety of transmission interfaces.

$ 816.00

With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.

$ 106.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, digests Colorimetric integrated tube to make the measurement safe and fast, can store 4000 sets of data and support multi-mode power supply.

$ 4721.00

The imported cold light source does not need to be preheated for 100,000 hours, the minimum display value is 0.001mg/L, supports standard measurement and continuous measurement modes, and the built-in large-capacity lithium battery realizes long standby, which can store 4000 sets of measurement data.

$ 816.00

Articles

Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Reflectometer Selection: Light Source Geometric Conditions and Contrast Ratio Testing
This article primarily discusses that when selecting a reflectometer, the geometric conditions of the light source are crucial, as they directly affect the accuracy of the measurement results.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Differences between xenon arc lamps, carbon arc lamps, and UV lamps in automotive interior and exterior light aging tests
Xenon lamps, carbon arc lamps, and UV lamps are three commonly used light sources in the photodegradation testing of automotive interiors and exteriors. Xenon lamps can simulate the full spectrum of sunlight, and by adjusting filters, they can match different environmental conditions, making them suitable for comprehensive evaluation of material aging.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.