Super Thermostatic Test Chamber

The super constant temperature test chamber maintains a constant temperature inside the chamber through heating and cooling systems. It is used to test the performance of materials at different temperatures, and is applied in industries such as coatings and plastics to examine the temperature resistance characteristics of products.
Selection
When selecting, consider that the temperature range should cover the testing requirements, the chamber size should accommodate the sample dimensions, temperature fluctuations should be controlled within ±0.5℃, configurations such as observation windows and test ports should be chosen based on actual usage, and pay attention to equipment energy consumption and maintenance cycles.

Terms

Instruments

Microcomputer thermostatic control system, Temperature Fluctuation +/- 0.05 ℃, display resolution 0.1 ℃, pump flow 8L/min, with break protection and over-temperature alarm function, support internal and external circulation.

$ 412.00

Microcomputer thermostatic control system, Temperature Fluctuation +/- 0.05 ℃, display resolution 0.1 ° C, with breaking protection and over-temperature alarm function, pump flow 8L/min.

$ 738.00

Microcomputer Intelligent Control system and imported PT100 temperature sensor, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, Pump Flow rate 8L/min, can establish a second thermostatic field, corrosion resistance and application temperature up to 300 ℃.

$ 590.00

Microcomputer precision thermostatic Control system, Temperature Fluctuation +/- 0.05 ℃, Pump Flow rate 8L/min, with break-even protection and over-temperature alarm function, the inner Tank and the box are made of stainless steel.

$ 624.00

With water and oil dual-use function, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, equipped with multiple Safety protection devices.

$ 677.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, Pump Flow rate 10L/min, with breaking protection and over-temperature alarm function, can establish a second thermostatic field, durable stainless steel material.

$ 627.00

Microcomputer Intelligent Control system and imported PT100 temperature sensor, Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with circulating pump can establish a second thermostatic field, Operating temperature up to 200 ℃.

$ 675.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, Pump Flow rate 10L/min, with breaking protection and over-temperature alarm function, can establish a second thermostatic field, durable stainless steel material.

$ 724.00

With the function of water-oil dual-use, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field and support the establishment of a second thermostatic field for external circulation.

$ 564.00

Microcomputer temperature control and PID adjustment technology, Temperature Fluctuation only +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 10L/min circulating pump, support internal and external circulation function, establish a stable second thermostatic field.

$ 456.00

With dual-use function of water and oil, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃. Adopt non-heat centrifugal circulation pump, configure external circulation function to establish a second thermostatic field, built-in multiple Safety protection devices.

$ 519.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and the porous U-shaped return design realizes a high degree of uniformity, Temperature Uniformity +/- 0.05 ℃, and supports the establishment of a second thermostatic field for external circulation.

$ 1209.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

Temperature range covering room temperature to 300 ℃, using PID automatic temperature control system accuracy of 0.01 ℃, domestic circulation without heat centrifugal pump to avoid temperature field interference, support external circulation to establish a second thermostatic field.

$ 798.00

Temperature range from room temperature to 300 ℃, Temperature Uniformity +/- 0.05 ℃, built-in non-heat centrifugal circulation pump to achieve uniform turbulence, support external circulation to establish a second thermostatic field.

$ 1363.00