It is designed with a digital thousand-minute differentiator, with a dual unit display of μm and mils, with a range of 0~ 10mm and a Graduation of 1μm, to achieve precise thickness control.
Using rigid polyester plate with foam rubber cushion, size 240x340mm, can absorb operating pressure, improve proofing Repeatability and uniformity, suitable for a variety of substrate testing.
The total film width of 90mm is divided into 10 gaps, the depth is gradually increased by 25μm, and the spacing is 1.5mm. The removable guide plate design is easy to operate on different thickness test panels.
Using brushless DC motor to achieve stepless speed regulation of 0~ 2000rpm, aluminum alloy heating plate Power 600W rises rapidly, temperature control accuracy +/- 1 ℃, heating plate temperature can be directly set and with safety restrictions.
Designed with 90mm application width and 25μm Graduation, with removable guide plate to ensure direct stretching, the sagging index is assessed through 10 aliquots, meeting ASTM standards.
Four-speed proofing speed is optional, up to 45m/min, using flat engraving plate for direct printing, supporting 95 × 149mm concave sample range, suitable for fast proofing of flexible substrates.
Grinding hard chrome metal pressure plate, adjustable temperature range -10~ 80 ℃, equipped with 10 point temperature transducer, through drying air flow to prevent condensation, ensure test repeatability, in line with a number of international standards.
Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Equipped with 0.4ml × 96 well coagulation plate, Oscillation Frequency from start to 3000rpm, swing amplitude 6mm, support timing function, suitable for uniform mixing of trace samples.
Impact method is adopted, the maximum thickness of test plate is 125mm, built-in bubble level and height limit ring, drop weight mass 1000g, punch diaMeter 20mm, die base aperture 27mm.
Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.
The demoulding frame design effectively reduces the accumulation of edge paints, is equipped with 4mm suspension hole to achieve non-marking vertical horizontal suspension, 0.8mm steel plate substrate to ensure test Stability, PE protective film to prevent transportation damage.
Using the principle of polarized light interference, equipped with 560nm full-wave plate, determinable or semi-Basis Weight measurement of internal stress, the aperture of the polarizer is 150mm, which supports continuous and rapid analysis of transparent materials.
Using metal layer plate structure, Temperature range -7~ 70 ℃, support 13 point temperature measurement, can simultaneously Spreader 6 samples, through drying air flow and layer temperature to achieve accurate film formation detection.
Measurement accuracy of 0.1mN/m using electromagnetic force equilibrating Sensor, support platinum plate method and platinum ring method dual method, automatic operation without manual calculation, real-time display Linear dispersion and save data.